General Use; Checks - GasTech GTA-4100R Operator's Manual

Dual processor controller card
Table of Contents

Advertisement

General Use

4

4.1 Checks

Complete the following procedure to place the GTA-4100R in normal operation.
1. Complete the mounting and wiring procedures described in the previous sections
2. Complete all configuration and programming procedures described in the previous sections
3. Verify that all wiring connections are correct and secure
4. Complete all installation procedures described in the sensors manual
5. Check each card is configured for the appropriate transmitter (sensor)
6. Check power being supplied to the GTA-4100R is correct (24VDC)
7. Turn on the incoming power at the power source
8. Verify the LCD display and status LEDs on each card are on
NOTE: The low alarm, high alarm, and fault circuits are not active for 60 seconds after power is applied to
the GTA-4100R. This time delay minimizes false alarms during transmitter warm-up. The display will be
flashing with the characters inverted.
Page 35
© 2008 GasTech Australia Pty Ltd

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents