In figure 18 is shown an example of DDMP performance curve using the Driver with default setting (without
changing the MAX and min speed values into the modbus register number 1 and 2).
In the indicated working point the correct analog voltage signal is 7V, because the Driver automatically
limits the performance in order to make the fan work in a safe operating area (see. Fig.7 at page 8).
Therefore even applying a voltage signal of 10V the speed of the fan doesn't change until the analog signal
goes below 7V.
Fig.18 – Performance curve explanation – Example DDMP 9/9
15
th
Rev. 2 – 10