Perform every 1-3 month(s) of usage
HOW TO PERFORM CITRIC ACID CLEANING
In order to prevent gas bubbles and bubbling-over, the Citric Acid Cleaner for
NOTE
Electric Water Boilers (CD-K03E-JU) is recommended for cleaning. To
purchase this cleaner, please visit an authorized Zojirushi dealer.
Preparation:
Check that the Filter is attached
to the Inner Container.
1
Put 1 package of the Citric Acid Cleaner
CD-K03E-JU in a cup and add warm water to
dissolve. Pour it into the Inner Container and
fill with water to the Maximum Water Level Line.
2
Close the Upper Lid, insert the Power Plug and press the
more than 3 seconds.
Beeps when the cleaning process begins.
Beeps when the cleaning process is completed.
Blinks
Beep
The square
2 lights will stop
2 lights will
shown on the
blinking and stay
blink.
Display rotates.
3
Unplug the Power Plug, detach the
Upper Lid and dispose water where
indicated "EMPTY FROM HERE."
(Please take precautions not to splash water
on the Hinge.)
4
To rinse, fill the Inner Container with
water. Boil and dispense about a cup of
hot water to rinse out the Spout, allow to
cool, then dispose the remaining water.
To cancel the Citric Acid Cleaning at any time,
unplug the Power Plug for more than 5 seconds.
Repeated citric acid cleaning may
NOTE
be necessary for hard-to-remove
residues or if water does not
dispense smoothly.
16
Do not drink
the water used
for citric acid
cleaning.
If the Filter is dirty, remove
NOTE
it from the Inner Container,
wash with a soft brush and
reinstall.
Do not fill over the
NOTE
Maximum Water Level
Line. (Hot water may spill
out, resulting in scalds.)
button for
Turns on
Cleaning time:
5 long beeps
Approx. 1.5 hours.
※Cleaning times may vary
depending on the amount
of water, water
temperature and room
temperature.
LCD display will
show a square as
illustrated.
on.
When disposing hot water:
Take precaution with the hot water
and steam. You may scald yourself.
Take precaution as hot water may
drip from the Spout, causing scalds.
If mineral or Alkalized Ionic water is
used, calcium tends to build up on
the surface of the Inner Container. If
scale accumulates on the Inner
Container or the Filter, boiling may
become louder than usual and water
may not dispense smoothly.
Frequent cleaning is recommended
when using mineral or Alkalized Ionic
water.

REPLACEMENT PARTS

Replacement parts may be available for an
additional charge. Please replace damaged parts
only with new parts.
When replacing parts, please record the model
number and part name beforehand. Then contact
the retail store where you purchased this product.
Q&A ON PRODUCT USE
Is it okay to use the product for
Do not fill the product with any liquid other than water. It may cause
heating liquids other than water?
malfunction, or may overflow and cause scalding.
Does the water need to be
To prevent scale from building up, please change the water at least once a
day.
changed every day?
Is it okay to use mineral
Yes. However, when mineral or Alkalized Ionic water is used, a floating
residue may develop or milky white substance may form on the surface of the
water or Alkalized Ionic
Inner Container. This is due to the ingredients in the water and is harmless to
water?
your health. Frequent cleaning is recommended.
I accidentally drank water while
Please follow the instructions shown on the package of the citric acid
performing the Citric Acid Cleaning.
cleaner CD-K03E-JU.
Is this harmful to my health?
It is safe to use the product unattended as it has an Automatic Shut-Off function (power
Is it okay to go out while
to the heater will be automatically turned off), which will be activated once it is empty of
water. However be careful not to repeat the boiling process without filling the Inner
the product is turned on?
Container with water, as the Nonstick Coating may discolor and peel.

TROUBLESHOOTING GUIDE

Condition
Cause
Power Plug is not connected to an
Water does not heat up.
electrical outlet.
Scale or other residue has accumulated
on the Inner Container.
Hot water has a
disagreeable odor.
You have not performed citric acid
cleaning regularly.
●A mild plastic odor may be
noticeable with a new product.
The product has not been used for a long
This odor will gradually fade
time.
away.
●You may smell chlorine (used
If tap water is used under Quick Temp
for sterilization of tap water)
Function, it will take an additional 15
after boiling.
minutes after heating completes at the set
temperature removing up to 80% of the
chlorine.
Parts Names
Parts Number
Inner Lid Gasket
625702-00
Filter
BF297053G-00
Citric Acid Cleaner for Electric
CD-K03E-JU
Water Boilers (30g×4 packets)
P.2
P.8
P.7
P.16
P.9
Please check the following
points before calling for service.
Remedy
Connect the Power Plug.
Perform citric acid cleaning.
(see pg.16)
Boil water, unlock and dispense
about 1 liter of hot water. Discard
the remaining. (see pg.7)
If this is an issue, use the regular Boil
mode instead. (see pg.12)
The regular Boil mode purges chlorine
in tap water by boiling completion.
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents