Commands For Id Control - Sharp PN-525U Operation Manual

Sharp lcd monitor operation manual
Table of Contents

Advertisement

Controlling the Monitor with a PC
Commands for ID control
The command examples shown on this page assume the
following connection and ID number set up.
ID number: 1
IDST ......... A monitor receiving this command sets its own ID
number in the parameter field.
Example:
IDST0001
OK
001
TIPS
You can automatically assign ID numbers by using the IDST
command with the Repeater control (see "Repeater control"
on page 27).
For example, using the command "IDST001+" automatically
sets the ID numbers, as shown below.
[Example]
ID number: 1
IDST001 +
WAIT
OK
001
OK
002
OK
003
OK
004
IDSL ........The parameter of this command sets the ID number
of the monitor. The monitor is subject to the next
command.
Example:
IDSL0002
WAIT
OK
002
VOLM0030
WAIT
OK
002
VOLM0020
OK
001
* The IDSL command is effective only once, for the
immediately succeeding command.
26
E
ID number: 2
ID number: 3
The ID number of this monitor is set to 1.
ID number: 2
ID number: 3
ID setting command with repeater control
"OK" response from ID number: 1
"OK" response from ID number: 2
"OK" response from ID number: 3
"OK" response from ID number: 4 (End)
The next command is for the monitor with
ID number: 2.
Searching for monitor with ID number: 2
Found monitor with ID number: 2
Sets volume of monitor with ID number:
2 to 30.
Processing
OK response from monitor with ID
number: 2
Sets volume to 20.
The volume of the monitor with ID
number: 1 (the one directly connected
to the PC) is set to 20.*
IDLK ........The parameter of this command sets the ID
number of the monitor. The monitor is subject to all
subsequent commands.
ID number: 4
Example:
IDLK0002
WAIT
OK
VOLM0030
WAIT
OK
VOLM0020
WAIT
OK
IDLK0000
WAIT
OK
VOLM0010
OK
ID number: 4
* The IDLK command remains effective until it is
canceled, or power is shut off.
IDCK ........Provides screen display of the ID number currently
assigned to a monitor, and the ID number currently
set for IDLK (if any).
Example:
(After executing IDLK0002)
IDCK0000
ID : 001
IDCK000 +
WAIT
ID : 001
ID : 002
ID : 003
ID : 004
Following commands are for the monitor
with ID number: 2.
Searching for monitor with ID number: 2
002
Found monitor with ID number: 2
Sets volume of monitor with ID number:
2 to 30.*
Processing
002
Sets volume of monitor with ID number:
2 to 20.*
002
Canceling fixed ID number setting
Canceling IDLK
002
Cancelation complete
The volume of the monitor with ID number: 1
001
(the one directly connected to the PC) is set
to 10. (IDLK is canceled.)
(Parameter has no meaning.)
Returned response. The ID
IDLK : 002
number is also displayed on the
monitor screen.
Repeater control (If a command
is used with repeater control, ID
designation using IDSL or IDLK is
IDLK : 000
canceled.)
IDLK : 000
IDLK : 000
IDLK : 000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-525upPn-525u - 52" lcd flat panel display

Table of Contents