Thermo Scientific Lindberg/Blue M VO Series Installation And Operating Manual
Thermo Scientific Lindberg/Blue M VO Series Installation And Operating Manual

Thermo Scientific Lindberg/Blue M VO Series Installation And Operating Manual

Vacuum ovens

Advertisement

Thermo
Fisher
Scientific
Vacuum Ovens
Installation
and
Operating Manual
Therrno
S C I E N T I F I C
Part of Thermo Fisher Scientific

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lindberg/Blue M VO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermo Scientific Lindberg/Blue M VO Series

  • Page 1 Thermo Fisher Scientific Vacuum Ovens Installation Operating Manual Therrno S C I E N T I F I C Part of Thermo Fisher Scientific...
  • Page 2 German-language version of these operating instructions shall be binding. Trademarks Thermo Scientific is a brand owned by Thermo Fisher Scientific, Inc. ® Lindberg Blue M and all other trademarks mentioned in the operating instructions are the exclusive property of the respective manufacturers.
  • Page 4: Table Of Contents

    Laboratory Vacuum Ovens Operation UP150 Controller ("P" Models only) Normal Controller Operation Single Setpoint Operation 6.2.1 Setting High Temperature Alarm Setpoint: 6.2.2 AccessingLocalMode 6.2.3 ExitingLocalMode ..........Programming Operation: Entering a Program 6.3.1 Entering Programming Mode...
  • Page 5 Installation and Operation Laboratory Vacuum Ovens Vacuum system includes inert gas injection valve, fresh air inlets, vacuum port to exhaust vacuum atmosphere, and controllable vacuum release vent port. The LindbergIBlue M VO Series is a family of laboratory vacuum ovens designed for drying, curing, outgassing, process Available Door Gaskets control, and applications which require elevated temperature in reduced atmospheres or vacuudpurge with non-flammable...
  • Page 6 Installation and Operation Laboratory Vacuum Ovens 1.3 Specifications Table 1. Dimensions W x (cm) Heater Shipping Model Voltage Exterior Weight Power Shipping Chamber Exterior (Approximate) 120 VAC, 50160 Hz, Single Phase 17.5 x 20 x 24.7 27.5 30 x 34.7 1.05 (22.9 35.6...
  • Page 7 Installation and Operation Laboratory Vacuum Ovens 114" Gas inlet vacuum por~ 114" Vent port Vent Vacuum 1" NPTvacuum port Power cord Overtemperature reset button Figure 1. Vacuum and Gas Connections WARNING! When installing, maintaining, or CAUTION! This product contains fiberglass wool or removing the refractory insulation.
  • Page 8 Note: Since the front panel display reads gauge pressure the value is relative to the local atmospheric pressure. Use in a location with reduced atmospheric pressure will result in the gauge displaying diminished vacuum levels.
  • Page 9: Operation . Up150 Controller ("P" Models Only)

    Installation and Operation Laboratory Vacuum Ovens Table CAUTION! Observe the following precautions when operating the oven: Wear protective eyeware. Wear protective gloves. Use tongs to insert and remove oven load. Do not allow the load to touch the oven walls. CAUTION! Do not attempt to operate the oven above the maximum rated temperature of...
  • Page 10 Installation and Operation Laboratory Vacuum Ovens 5.2 Setting the Temperature parameter to the desired overtemperature limit in O F . To set the temperature to the desired setpoint, complete the 11. Press and release SETIENT to advance to the P parameter and following steps: change its value to 16.2.
  • Page 11 Installation and Operation Laboratory Vacuum Ovens Auto Tuning the Controller Factory settings are provided for general purposes, but your process can be enhanced through the auto tune feature. For a given process temperature and product load, auto tuning maximizes the performance of the chamber by operating with the quickest response and minimal temperature overshoot.
  • Page 12: Normal Controller Operation

    Installation and Operation Laboratory Vacuum Ovens UP150 Controller Table UP150 Parameter Functions parameter Description Value Operating parameters (access by holding the SETENT key) Program Hold Segment Advance Control mode Auto tuning 32.4 Proportional band 1384 Integral time Derivative time RUN m m HOLD Heat cycle time Sensor filter PV bias (offset)
  • Page 13: Single Setpoint Operation

    Installation and Operation Laboratory Vacuum Ovens 6.2 Single Setpoint Operation The following sections describe how to operate the controller in To exit Single Setpoint or Local Mode and turn off the energy to single setpoint (local) mode. Use this mode when you only need the heaters: to run the oven with a specific setpoint and do not require a 1.
  • Page 14: Entering Program Parameters

    Installation and Operation Laboratory Vacuum Ovens Entering Program Parameters 9. The next parameter, "SP4" is normally the dwell segment. Select the same target temperature as "SP3" with the arrow The first display is the Start Set Point parameter, shown as " S S P buttons, then press and release the 'SETENT' button twice in the upper display.
  • Page 15: Runningaprogram

    Installation and Operation Laboratory Vacuum Ovens 6.3.3 Running a Program Auto Tuning the UP150 Controller To run a program such-as the one outlined above, press and hold Auto tuning maximizes the performance of the chamber at a the 'DOWNIRUN' button making the 'RUN' indicator selected temperature with the product load's characteristics, by illuminate.
  • Page 16: Temperature Offset Procedure

    Installation and Operation Laboratory Vacuum Ovens Temperature Offset Procedure 1. Make sure the indicators beside " RUN and "L" on the controller face are off. If they are on, press and hold the The purpose of this procedure is to create an offset in the displayed temperature measurement for the Yokogawa model 2.
  • Page 17: Maintenance

    Installation and Operation Laboratory Vacuum Ovens 7 Maintenance 7.1 General Maintenance WARNING! Disconnect oven from main power CAUTION! Maintenance should only be performed before attempting any maintenance to oven or its controls. Regular maintenance is required to keep the oven running at WARNING! Disconnect oven from main power optimum levels.
  • Page 18: Troubleshooting

    8 Troubleshooting WARNING! Troubleshooting procedures involve working with high voltages which can cause injury or death. Troubleshooting should only be petformed by trained personnel. This section i s a guide to troubleshooting oven problems. Refer to Table 6 for troubleshooting procedures. Table 6.
  • Page 19: Replacementparts

    Installation and Operation Laboratory Vacuum Ovens All quantities are one each unless noted. Table Replacement Parts Silicone Gasket Door Pull Handle, SA and SC Units Pull Handle, A and C Units Door Magnet Catch Levelling Feet (4) 38026H01 (4) 38026H01 (4) 38026H01 Aluminum Full Shelf (2) 38028H02...
  • Page 20 5/18/99 NOT TO SCALE 1218 1824 al l H I L Reference UP150 YOKOGAWA CONTROL Over Tenperatwe Reset Thernostot 103508 NEMA 5-15? M V A C...
  • Page 21 Europea 2002/96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici (WEEE). È marcato col seguente simbolo. Thermo Scientific ha stipulato contratti con una o diverse società di riciclaggio/smaltimento in ognuno degli Stati Membri Europei. Questo prodotto verrà smaltito o riciclato tramite queste medesime. Ulteriori informazioni sulla conformità...
  • Page 22 Important For your future reference and then contacting the factory, please have the following information readily available: Model Number: ___________________________ Serial Number: ___________________________ Date Purchased: ___________________________ The above information can be found on the data plate attached to the equipment. If available, please provide the date purchased, the source of purchase (manufacturer or specific agent/rep organization), and purchase order number.
  • Page 24 www.thermoscientific.com...