Download Print this page

Schlage M400 Series Installation Instructions Manual page 6

Single electromagnetic locks
Hide thumbs Also See for M400 Series:

Advertisement

5
Install mounting bracket into frame.
5a
Attach mounting bracket temporarily
Install two middle screws into slots and partially tighten.
5b
Remove wiring cover.
5d
Align magnet to armature.
Close door.
Press magnet to fully engage with armature.
Mark bracket location.
Mark here
Press magnet to armature
6
Pull wires
Partially
tighten
Actual Size
Reinforced
Metal
Sheet
Metal
5c
Slide magnet onto bracket.
5e
Fully attach bracket.
Remove magnet from bracket.
Check bracket alignment with marks.
Fully tighten two screws in slotted holes.
Drill four (4) remaining holes.
Fully tighten all screws.
Actual Size
Sheet
Metal
E
I D
T S
O U
Check
alignment
Fully tighten
all screws
Drill four (4) holes
Reinforced
Metal
Use 10-24 tap
if reinforced metal