Hussmann DSF Installation & Operation Manual
Hussmann DSF Installation & Operation Manual

Hussmann DSF Installation & Operation Manual

Open fish service case
Table of Contents

Advertisement

/CHINO
Installation
DSF, DSFI, DSFM, DSFN
& Operation
Manual
OPEN FISH SERVICE CASE
REV. 0317

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann DSF

  • Page 1 /CHINO Installation DSF, DSFI, DSFM, DSFN & Operation Manual OPEN FISH SERVICE CASE REV. 0317...
  • Page 2: Table Of Contents

    Plexiglass and Acrylic Care .................. 35 The serial number and shipping date of all equipment Cleaning ....................... 35 has been recorded in Hussmann’s fi les for warranty and Antistatic Coatings ....................35 Maintenance ..................36 replacement part purposes. All correspondence pertaining...
  • Page 3: Cut And Plan Views

    Ledge Light Ledge Lights 2" " " " " 2" " " DSF Inlet DSF Center Display Narrow Depth Deeper Display Scale = 1/2" Scale = 1/2" STRAIGHT GLASS Swing Out 7 7/8 18 5/8 17 5/8 LED LIGHTS 5 3/8...
  • Page 4: Installation

    Installation Location The refrigerated merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric fans, ovens, open doors or windows (etc.) to create air currents around the merchandiser, as this will impair its correct operation.
  • Page 5: Leveling

    Fasten along the top edge, or center, with leaves gaps at the joint. #10 X 3/3” sheet metal screws. 2-part epoxy Silicone DSF 4 & DSF 2 & Deeper Depth Narrow Depth...
  • Page 6: Scale Stand Installation Instructions

    Installation (Cont'd) Scale Stand Installation Instructions 1.- Set Scale Stand to desire location 2.- Drill holes and screw in place (with screws provided – Hex Tek S/S 10-16 X ½”) Note: Use hole pattern...
  • Page 7: Wrapping Boards Installation Instructions

    Installation (Cont'd) Wrapping Boards Installation Instructions Step 2: Measure 10 inches from top of the case. Step 1: Measure 6 inches from wrapping board end. Note: Line up 6 inch mark with 10 inch mark. Step 3: Use bracket center hole to align with cross mark. Note: Use pencil/marker to mark hole pattern.
  • Page 8 Installation (Cont'd) Step 6: Install upper support bracket Step 7: mount wrap board on top of bracket using a ¼” Step 8: screw bracket into wrap board spacer to have a gap between rear wall and board. (screws provided -#8 X 1 ¼”) Installation Complete...
  • Page 9: Bumper Installation Instructions

    Installation (Cont'd) Bumper Installation Instructions Step 2: Use silicone lubricant to help the Step 1: Make sure the aluminum channel and end caps bumper slide into the channel. are installed. Step 3: Starting on one end: while inserting the bumper, Step 4: As you insert the bumper into the channel with push it up against the end cap to prevent one hand, pull the bumper toward you with...
  • Page 10: Dsf End Wing Assembly Instructions

    Installation (Cont'd) DSF End Wing Assembly Instructions Parts and Components List Part Total Quantity Description Sheet Number 1H12007300 Curved Plex Wing Wing 1H16223300 Curved Plex Wing, 54" FLAT TOP 1H12008300 Straight Plex Wing Left Wing Channel Female Hinges + Wing Channel...
  • Page 11 Installation (Cont'd) Rear of Case Front of Case 1H12008300 Straight Glass Model 1H12007300 Curved Glass Model 1H16223300 Curved Glass Model, 54" FLAT TOP This part is used when health codes require a horizontal end shield at 54" from the ground Left Hinge Weldment Right Hinge Weldment Left Wing Channel Weldment...
  • Page 12 Installation (Cont'd) Bumper Components Plexiglas Spacer .750 .875 175-01-5002 3 3/4" Length 025880 3.750 50 Series End Cap 50 Series Bumper Length = 3" Wood Screw Binding Post 1.000 .188 175-01-0369 x 10 .500 1/2" Post 300-03-0641 10-24 x 1" Machine Screws 300-03-0620 8-32 x 1"...
  • Page 13: Channel Weldment Assembly

    Installation (Cont'd) Channel Weldment Assembly (Left Wing Channel Shown) 1) Refer to the critical measurements section of the instructions for reference dimensions. (Page 16) 2) Check Position • Hinges over outer side of end panel • Holes on outer side of end panel •...
  • Page 14: Place Hinges

    Installation (Cont'd) Place Hinges (Left Wing Assembly Shown) Inner side of DSF Case RIGHT HINGE WELDMENT LEFT HINGE WELDMENT Outer side of DSF Case Assemble Right Wing in a Mirrored Configuration NOTES: 1) Pins will face in opposite directions, away from the center of the channel.
  • Page 15: End Wing Attachment

    Installation (Cont'd) End Wing Attachment (Left Wing Shown) 175-01-0369 Inner side of DSF Case 300-03-0610 Outer side of DSF Case 1) Place the plex wing into channels on the hinges. 2) Align all 4 holes on the wing with respective holes on hinges.
  • Page 16: Bumper Installation

    Installation (Cont'd) Bumper Installation 1) Locate the Bumper as Indicated Below 2) Mark this Location 3) Positiion Bumper Channel on End • Install Both End caps on Aluminum Channel 4) Use 300-03-0641 x 4 to Fasten to End Panel 5) Press Bumper over Exposed Screws and Ends Caps 26.375 With wing folded down, 27.438...
  • Page 17: Critical Dimensions And Measurements

    Installation (Cont'd) Critical Dimensions and Measurements CALLOUT DESCRIPTION MODEL VALUE (Inches) Normal Distance from the ground to the bottom of 27-1/4 ~ 27-3/8 the hardware (Sampled at the ends) Overall Hardware depth (Hardware fully closed) 3-5/16 ~ 3-7/16 Overall Distance from the ground to the highest 54-3/8 ~ 54-1/2 point on glass (Wings Up) Normal Distance from Wing Channel to highest...
  • Page 18: Dsf Hardware Notes

    2) Loctite 242 thread locker must be applied to the threads of all screws used to attach the glass hardware to the merchandiser. Installing and Adjusting DSF Glass • Glass is Heavy and can cause serious injury. • Professional installation recommended.
  • Page 19: Glass Stop And End Wing Final Position Notes

    Installation (Cont'd) STEP 4: ATTACH SHIM TO GASKET IN DESIRED POSITION USING CLEAR 3/8" DOUBLE SIDED TAPE STEP 5: REPLACE SHIMMED GLASS AND TIGHTEN CASE ALL CLAMP SCREWS INTERIOR EVENLY AND SECURELY PLACE SHIM HERE TO ROTATE GLASS UPWARD PLACE SHIM HERE TO ROTATE GLASS DOWNWARD STEP 6:...
  • Page 20 Installation (Cont'd) Boston Series 2000 Boston 2000 Eco Series NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the fl exible top to ensure a proper fi t. NOTE: Rigid Top: Do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
  • Page 21 Installation (Cont'd) Boston 1000 Series 2b. Rigid Top: Snap the Rigid Top over the Rigid Base. NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the fl exible top to ensure a proper fi t. NOTE: Rigid Top: Do not over cut. Installation 3.
  • Page 22 Installation (Cont'd) Corrigan Retrofi t Instructions Step 1: Marking and Drilling Pilot Holes If the existing Misting Channel does not have 1/8" diameter holes in the location shown, these holes will have to be marked and drilled. Option 1: Mark the two hole locations as specifi ed in the diagram.
  • Page 23 Installation (Cont'd) Step 2: Attach misting nozzle to misting bracket Step 3: Attach Nozzle/Bracket assembly to Misting The spraying end of the nozzle must point toward the end Channel of the bracket with two holes. The nozzle will protrude into the oblong cutout. See the diagram below.
  • Page 24: Plumbing

    Plumbing Waste Outlet and P-TRAP plumbing system fl oor drains should be at least 14” The waste outlet is located off the center of the case on off the center of the case to allow use of the P-TRAP one side allowing drip piping to be run lengthwise under the pipe section.
  • Page 25: Humidifi Cation

    The only other The DSF is capable of maintaining superb product quality with the installation of the proper controlling devices. moisture in the case is that which is in the product.
  • Page 26: Start-Up

    Manifold Flush System Start-up General Description Turn on the fan circuit. Check to see if the fan for the Twice a day for two (2) minutes, a high pressure water humidity system is running. Remove the right hand bottom stream will fl ush most residue build-up from the bottom of pan (when facing the front of the case), then the TXV cover.
  • Page 27: Refrigeration

    Defrost is located on the same side of the case. If you are looking times should be as directed in the DSF, DSFM technical at the case from the back, it is on the left hand side.
  • Page 33: Electrical

    LED Driver Location The receptacle that is provided on the exterior back of these The DSF, DSFM has no lights other than Optional Ledge models is intended for computerized scales with a fi ve amp lights. The drivers for ledge lights are located in the fi xture maximum load, not for large motors or other high wattage itself.
  • Page 34: Ashrae Color Code

    9. In the Deli, Meat and Fish cases, completely cover product. Hussmann cases were not designed to “heat up” the product each night with a clean damp cloth or or “cool down”...
  • Page 35: Case Cleaning

    2. Rinse with hot water, but do not fl ood. 3. Apply the sanitizing solution according to the Cleaning manufacturer’s directions. Hussmann recommends using a clean damp chamois, or a paper towel marketed as dust and abrasive free with 210 ® 4. Rinse thoroughly.
  • Page 36: Maintenance

    Copper Coils break down the passive layer and rust your stainless The copper coils used in Hussmann merchandisers may steel. Other deposits from food preparation and be repaired in the fi eld. Materials are available from local service must be properly removed.
  • Page 37: Electrical Wiring Diagrams

    Heating cleaners that contain Electrical Wiring Diagrams 3011870 DSFM-6 W/LED DSFM DSFM-18 W/MAIN SWITCH 3011666 DSFN DSFN-16-8I-8I-R 3013400 3013401 DSF-12-3D-6I-3D-R 3005959 DSF-24-4D-6I-4D-6I-4D 2-TIMER SWITCHES 3003378 DSF-24-10I-45O-10-I-R W/MAIN SWITCH...
  • Page 38 REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY LOADING A ECN-CAP-0003047 2016/07/25 RELEASED TO PRODUCTION 120V 2. 3 CIRCUIT #2 DUPLEX CANOPY LOADING 125-01-3178 120 V 15. 0 LIGHT CIRCUIT 0. 2 7A 29. 4 W @ 120V NOTE: CASE MUST BE GROUNDED ~120 VAC - 1Ø...
  • Page 39 REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY LOADING A ECN-CAP-0003047 2016/07/21 RELEASED TO PRODUCTION 120V 5. 2 CIRCUIT #2 CIRCUIT #3 DUPLEX DUPLEX LOADING LOADING (4) 125-01-3178 (4) 125-01-3178 120 V 120 V 15. 0 15.
  • Page 40 REVISION HISTORY CIRCUIT #1 DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY LOADING A ECN-CAP-0003235 2016/08/16 RELEASED TO PRODUCTION 120V 4. 5 CIRCUIT #2 CIRCUIT #3 DUPLEX DUPLEX LOADING LOADING (4) 125-01-3178 (4) 125-01-3178 120 V 120 V 15. 0 15.
  • Page 41 MOP-15. 0 MOP-15. 0 MOP-15. 0 MOP-15. 0 MOP-15. 0 MOP-15. 0 MATERIAL - N/A DATE DRAWN - 8-16-16 DIAGRAM-DSF-12-3D DRAWN BY -CRAIG BOOREY ECN-CAP-0003235 REF - REVIEWED BY -CRAIG BOOREY -6I-3D-R APPROVED BY - CRAIG BOOREY SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES.
  • Page 42 L1 N RELAY (NC) CIRCUIT #1 MARS 90341 125-01-1343 MATERIAL - N/A 14' SECTION DATE DRAWN - 5-5-16 DIAGRAM-DSF-24-4D DRAWN BY -CRAIG BOOREY ECN-CAP-0001581 REVIEWED BY -CRAIG BOOREY REF - -6N-4D-6N-4D-R APPROVED BY - CRAIG BOOREY SHEET 1 OF 2 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES.
  • Page 43 BROWN PURPLE PURPLE BROWN 125-01-0311 CIRCUIT #1 MATERIAL - N/A DATE DRAWN - 4-5-16 DIAGRAM-DSF-24-10I DRAWN BY -CRAIG BOOREY ECN-CAP-0000240 REF - REVIEWED BY -CRAIG BOOREY -45O-10I-R APPROVED BY - CRAIG BOOREY SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES.
  • Page 44: Appendices

    Public Health will use the temperature of the product in installation instructions and recommendations determining if the refrigerator will be allowed to display provided by Hussmann for the installation potentially hazardous food. For the purpose of this of each individual type refrigerator.
  • Page 45: Appendix D. - Recommendations To User - Refrigerated

    1 inch internal 12. Are the shelf positions, number, and size diameter. A test thermometer scaled only other than recommended by Hussmann? in Celsius or dually scaled in Celsius and 13. Is there an improper application or control Fahrenheit shall be accurate to 1°C (1.8°F).
  • Page 46 Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling. For further technical information, please log on to http://www.hussmann.com/products/DSF.htm...
  • Page 47 Additional copies of this publication may be obtained by contacting: unit. Hussmann® Chino They can be found on a small metal plate on the unit. 13770 Ramona Avenue • Chino, California 91710 Please note them below for future reference.

This manual is also suitable for:

DsfmDsfiDsfn