5)
Press assembly into the front housing.
6)
Install the mechanical seal with retaining clips onto the drive shaft being careful not
to damage the seal's wedge on the keyway. Then remove the retaining clips. Slide
the seal into the seal chamber.
4)
Remove the drive side seal seat (24) and the seal seat gaskets (18) or O-rings from
the gland.
5)
Install new seal seat gaskets or O-rings on the seal seat and install into gland.
6)
Install gland, gland screws and lock washers. Tighten gland screws to 90 in-lbs (10
NM).
7)
Using an Allen (Hex) Key slide seal retainer (metal cartridge) to position set screws
centrally within the 1/8 inch NPT openings. Rotate shaft and tighten all four (4) set
screws.