  • Page 1 Slim tube HE Complete guide for Quantum products...
  • Page 2: Table Of Contents

    Table of contents Slim tube HE fitting Thank you for choosing the slim tube HE option, designed Slim tube HE fitting ...................1 to provide comfortable, non-occluding fittings with added Components of a slim tube HE hearing instrument........2 high frequency emphasis. Slim tube HE sizes ..................2 Whether you are an experienced fitter of slim tube Measuring for an accurate slim tube HE length ........3...
  • Page 3: Components Of A Slim Tube He Hearing Instrument

    Components of a slim tube HE Slim tube HE sizes hearing instrument Slim tube HE is available in four different lengths to meet the needs of your clients. The red or blue numeric Use the diagram below to identify some of the code on the slim tube identifies the ear to which it components of a slim tube HE hearing instrument: belongs (blue = left ear;...
  • Page 4: Measuring For An Accurate Slim Tube He Length

    Measuring for an accurate slim tube HE length Choosing the correct slim tube HE length will ensure a 2. Hold the measurement tool with the more accurate, comfortable fit. The measurement tool appropriate blue or red color code included in the kit allows for a quick and simple marking (for the left or right ear) with measurement and has the following features: your thumb placed on the ear diagram.
  • Page 5: Choosing The Correct Domes

    Choosing the correct domes Attaching and removing domes Do an otoscopic examination of the client’s ear canal. To attach the dome, push the dome onto the slim tube HE Based on the examination, choose an appropriate dome until it touches the plastic ring. to fit the ear canal.
  • Page 6: Attaching And Removing The Slim Tube He

    Attaching and removing the Modifying the slim tube HE to slim tube HE improve fit To attach the slim tube HE: In some cases, you might find that the slim tube HE does not lie close to the side of the head or follow the shape of 1.
  • Page 7: Positioning The Hearing Instrument On The Ear

    Positioning the hearing instrument on the ear Once you have attached the slim tube HE with dome to When looking at your client face-to-face, you should the hearing instrument, you are ready to place the not see the slim tube HE sticking out. hearing instrument on the client’s ear.
  • Page 8: Cleaning The Slim Tube He And Dome

    Cleaning the slim tube HE and dome The slim tube HE and dome need to be changed every 4. Using the cleaning pin three months or when they become stiff or brittle. As part provided in the kit, of the fitting, you will need to counsel the client on how gently insert the to clean the dome and the inside of the slim tube HE.
  • Page 9 Contact us International - +1 519 895 0100 European Representative & Germany - +49 711 658538 0 Canada - 1 800 265 8255 U.S. - 1 800 888 8882 U.K. - 01925 247810 France - 0821 02 9000 Netherlands - +31 88 600 88 10 China - 512 6258 2258 New Zealand - 0800 864 8766 Australia - 1800 212 313...