Controlling Temperature; Nighttime Control; Controlling Relative Humidity (Rh); Lighting Control - Titan Controls HyperioN 2 Instruction Manual

Wireless environmental /lighting master controller
Table of Contents

Advertisement

Controlling CO2:
During the Daytime, when the CO
minus the hysteresis (the setpoint minus 100 ppm), the CO
be activated. The CO
desired setpoint. When the CO
will then turn off. Each time the Exhaust output is activated, the CO
output will automatically be turned off to prevent wasteful venting of CO

Nighttime Control:

During the Nighttime, the Hyperion
to keep its environment at the desired levels. During Nighttime mode, the
LED on the remote sensor will be off but quickly flash every three seconds,
and the Hyperion
in the upper right-hand corner.

Controlling Relative Humidity (RH):

The Hyperion
Daytime Control section; however, it will use a separate Nighttime
setpoint. This allows the user to tightly control the RH to provide an
ideal growing environment.

Controlling Temperature:

The Hyperion
in the Daytime Control section; however, it will use a separate
Nighttime setpoint. This allows the user to accurately control the
temperature to provide an ideal growing environment during day and
night conditions.
Controlling CO2:
During Nighttime, the CO
CO
levels are controlled by ventilation (instead of enrichment). If the
2
CO
levels climb above the Nighttime setpoint, the Exhaust output will
2
activate to lower CO

Lighting Control:

The Hyperion
2 lighting controller is specifically designed for operation
®
of an indoor garden lighting system. The controller will operate your lights
for any sequence over a 24-hour period. The controller can handle up to
a maximum of four (4) 1000 watt HID metal halide, high pressure sodium
(HPS), ceramic (LEC) or LED grow lights. The Hyperion
provides up to 20 amps of capacity on a standard 240 Volt circuit.
output will remain on until the reading rises to the
2
2 remote controller will show the night symbol for MODE
®
2 maintains its environment's RH as described in the
®
2 maintains its environment's temperature as described
®
output is never active: the environment's
2
levels below Nighttime CO
2
reading drops below the setpoint
2
reading reaches the setpoint the output
2
2 uses the Nighttime control setpoints
®
8
output will
2
setpoint.
2
2 lighting controller
®
2
.
2