Westinghouse 2400i Instruction Manual page 37

Digital inverter generator
Table of Contents

Advertisement

PROBLEM
Engine stops during
operation.
TROUBLESHOOTING
POTENTIAL CAUSE
1.
Generator is out of fuel.
2.
Fuel is contaminated with
water or other foreign
substance.
3.
Fuel cap vent is in the OFF
position.
4.
Fuel control switch is in the
OFF position.
5.
Low oil level.
6.
Spark plug boot is not
properly connected onto
spark plug terminal.
7.
Overload or short circuit in
the connected 240-Volt AC
load.
8.
If above possible causes
are checked and eliminated,
generator may be faulty.
SOLUTION
1.
Check fuel level and add fuel if necessary.
2.
Drain fuel and refill with fresh fuel.
3.
Move fuel cap vent to the ON position.
4.
Move fuel control switch to the ON position.
5.
Check oil level and add oil if necessary.
6.
Push spark plug boot firmly onto spark plug.
7.
Disconnect all electrical cords and devices from
generator. Re-start generator with ECO throttle
switch in the OFF position and then re-connect
electrical loads individually if possible. If only single
load, check running and starting power demands
versus generator's rating.
8.
Take generator to an authorised Westinghouse
service dealer.