Gas Requirements And Hookup - Thermador PCG305W Installation Instructions Manual

Professional series rangetops
Hide thumbs Also See for PCG305W:
Table of Contents

Advertisement

Available languages

Available languages

4. Leave protective film over brushed-metal surfaces, to
protect finish from scratches, until the rangetop is
installed in its final position.
5. Use a 7/16" box wrench to remove the four (4) bolts
from the bottom of the pallet and discard.
6. Attach the backguard, if applicable, before sliding the
appliance into the final installed position.
7. Lift and place the rangetop in the countertop
opening. Be careful not to pinch the power cord or
gas inlet. Care should be used not to scratch the
countertop.
8. Make sure that the power cord is free and hanging
loose.
9. The rangetop must be level for proper performance.
10. Replace the cooking grates, griddle plate, and burner
caps. Ensure that the burner caps are correctly seated
on the burner bases.
Assembling the Grill (not all models)
Refer to "Using the Electric Grill" in the Use and Care
Guide.
Griddle Tilt Adjustment (not all models)
Refer to "Using the Electric Griddle" in the Use and Care
Guide.

Gas Requirements and Hookup

Gas Hook Up
A manual gas shut-off valve must be installed external
to the appliance, in a location accessible from the
front, for the purpose of shutting off the gas supply.
The supply line must not interfere with the back of the
unit. Make sure the gas supply is turned off at the
manual shut-off valve before connecting the
appliance.
The installer should inform the owner of the location
of the gas shut-off valve. Make sure all users know
where and how to shut off the gas supply to the
rangetop.
The gas supply connections shall be made by a
competent technician and in accordance with local
codes or ordinances. In the absence of local codes,
the installation must conform to the National Fuel Gas
Code ANSI Z223.1/NFPA54-current issue or, in
Canada, the Natural Gas and Propane Installation
Code, CSA B149.1.
The gas supply pressure for checking the regulator
setting shall be at least 1 in. WC (249 Pa) above the
manufacturer's specified manifold pressure.
Use a ¾'' (19 mm) flex line to connect between the
gas supply and the appliance gas inlet. The gas supply
line connection is located at the left rear of the
appliance. The appliance gas inlet connection is ½''
(12.7 mm) NPT.
¾" (19) external threads
¾" (19) external threads
½" (12.7) internal threads
½" (12.7) internal threads
Use caution to avoid crimping the ¾'' (19 mm) flex
line when making bends. Suggested length of flex
line is 48" (1,219 mm); however, please check
local codes for your area's requirements before
installation.
Use pipe sealing compound or Teflon® tape on the
pipe threads. DO NOT apply sealing compound or
tape to flare fittings. Take care not to apply excessive
pressure when tightening the fittings.
All installer-supplied parts must conform to applicable
codes.
Leak testing of the appliance shall be in accordance
with the following instructions.
Turn on gas and check supply line connections for
leaks using a soap and water solution.
Bubbles forming indicate a gas leak. Repair all
leaks immediately after finding them.
WARNING
DO NOT use a flame of any kind to check for gas
leaks.
{
¾" (19)
¾" (19)
Flex line
Flex line
inches (mm)
Page. 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcg486wlPcg366wPcg364wdPcg364wlPcg486wd

Table of Contents