3. Drawing External Appearance
Weight
Model
KPG-36X
4. About selecting USB/UART
For using USB (Up to 12Mb/s USB Speed), Slide the SW of KPG-36X to USB.
For using UART (RS-232C), Slide the SW of KPG-36X to UART.
5. PC tuning
Connect the wires to the PCB in the connector case of KPG-36X.
For output the wires out of the connector case, need to process the connector case.
・Connect AF Voltmeter to 2pin and 3pin of the connector PCB.
・Remove the 5pin wire from the connector PCB.
・Connect Audio generator to the 5pin of the connector PCB.
・Connect Audio generator to the 6pin of the connector PCB.
・Connect the 4pin to the GND.
(Refer to below figure)
Slide the SW of KPG-36X to UART for PC tuning.
Remove the screw
Connector case
2(No.RQ070)
(800)
weight(kg)
0.08
.
1500
UART/USB
SW
30±
10
(645)