Keys Description - 3onedata CAN485 User Manual

Interface converter
Hide thumbs Also See for CAN485:
Table of Contents

Advertisement

Shenzhen 3onedata Technology Co., Ltd
Baud rate: baud rate of CAN-Bus standard, the baud rate is CIA recommended list.
Frame type: in frame type conversion of the CAN-Bus message, a standard frame and extended frame optional,
does not support remote frame.
Receiving filter mode: receiving converter, filter on CAN-Bus message.
Filtering options: filtering invalid or effective filtering.
Receive frame options: receive only the standard frame or receive only the extended frame.
The ID option: do not distinguish between ID or distinguish ID (ID associated with receiving the identifier).
Filter acceptance code (HEX):
Fill in the data format is 16 hexadecimal form, with "spaces" separated between each 8 bit byte.
If it is a standard frame, then the frame of ID is only 11, so the maximum filtering acceptance code" 0x07 FF ", the
invalid part of more than 11-bit identifier, software only low 11-bit identifier.
If the extended frame, then the frame of ID is 29, so the maximum filtering acceptance code" 0x1F FF FF FF ", the
invalid part of more than 29-bit identifier, software only low 29-bit identifier.
Filter mask off code (HEX):
Fill in the data format is 16 hexadecimal form, with "spaces" separated between each 8 bit byte.
If it is a standard frame, then the frame of ID is only 11, so the maximum filtering acceptance code" 0x07 FF ", the
invalid part of more than 11-bit identifier, software only low 11-bit identifier.
If the extended frame, then the frame of ID is 29, so the maximum filtering acceptance code" 0x1F FF FF FF ", the
invalid part of more than 29-bit identifier, software only low 29-bit identifier.
If the filter acceptance code and filter mask off code according to phase and operation value equal to frame ID and
filter mask off code according to phase and operation value, then receives the frame, or else not to receive.

5.2.4 Keys description

Default setting: can be restored to the factory default parameters.
Read setting: the existing parameters of converter is read out and displayed on the panel.
Write setting: after setting the parameters in, click the button to write configuration parameters of converter.