Table 2. Operating Specifications
Characteristic
1, 2
Supply voltage (V
):
supply
pressure ranges >60 mbar | 6 kPa | 1 psi
pressure ranges <40 mbar | 4 kPa | 20 H
Supply current (at 5.0 Vdc supply)
TSC Series
NSC Series
Operating temperature range
Compensated temperature range
Startup time
TSC Series output resistance
1
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
2
Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
3
Operating temperature range: The temperature range over which the sensor will produce an output proportional to pressure.
4
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified perfor-
mance limits.
Table 3. Environmental Specifications
Characteristic
Humidity
Vibration
Shock
1
Life
Solder reflow
1
Life may vary depending on the specific application in which the
sensor is utilized.
Table 4. Wetted Materials
1
Component
(Pressure Port)
high temperature
Ports and covers
polyamide
Substrate
alumina ceramic
Adhesives
epoxy, RTV
Electronic
components
1
Contact Honeywell Customer Service for detailed material information.
2
Honeywell Sensing and Control
O
2
3
-40 [-40]
4
J-STD-020-D MSL1 (unlimited shelf life when stored at less than 30 °C and 85 %RH)
Port 1
Port 2
(Reference Port)
high temperature
polyamide
alumina ceramic
epoxy, RTV
silicon
silicon, glass, gold
Min.
Typ.
1.5
5.0
2.7
5.0
0.6
1.5
0 [32]
2.5
0% to 95% RH, non-condensing
MIL-STD-202F, Method 214A, Condition 1E (15 g, 10 Hz to 2 kHz)
MIL-STD-202F, Method 213B, Condition F (100 g, 6 ms duration)
1 million pressure cycles minimum
CAUTION

PRODUCT DAMAGE

• Ensure liquid media is applied to Port 1 only; Port 2 is not
compatible with liquids.
• Ensure liquid media contains no particulates. All
TruStability® sensors are dead-ended devices. Particulates
can accumulate inside the sensor, causing damage or
affecting sensor output.
• Recommend that the sensor be positioned with Port 1 facing
downwards; any particulates in the system are less likely
to enter and settle within the pressure sensor if it is in this
position.
• Ensure liquid media does not create a residue when dried;
build-up inside the sensor may affect sensor output.
Rinsing of a dead-ended sensor is dificult and has limited
effectiveness for removing residue.
• Ensure liquid media are compatible with wetted materials.
Non-compatible liquid media will degrade sensor
performance and may lead to sensor failure.
Failure to comply with these instructions may result in
product damage.
Max.
12.0
6.5
1
2.2
85 [185]
85 [185]
5
Parameter
Issue 5
50063864
Unit
Vdc
mA
°C [°F]
°C [°F]
ms