Time switch
RondoRex w21
NT 29 17 54 02
Safety notes
• Installation of these products should only be undertaken by a qualified electrician.
• The operational and electrical safety is only guaranteed, if the product is installed using its proper accessories, in a position as specified in the
installation instructions (distribution panel, surface or wallbox (front of panel).
• Any interference with the product makes the guarantee void.
• If the time switch is mounted near equipment where heat produced raises the local ambient above 55°C. Then a space should be put between
the time switch and the equipment (e.g.
Function
The RondoRex w21 is a digitall 7 day time switch with a round segmented display for general rail mounting use. Up to 4 program
pictures per day can be set. A program picture incorporates both on and off time. The copying function enables program to be copied to other days.
Different programs can be set on each day. The minimum switching time is 1 minute. Program pictures are protected but can be overlaid by other
programs. Programs are displayed with a minimum segment size of 15 minutes. Time of day and weekday number are
digitally displayed.
Presentation
Constant clock symbol = Time switch running
Blinking hand symbol = continuous manual operating
1 segment = 15 minutes, 4 programs per day max.
Change from day to hour, minute, programming,
Connection
1
space module code 044 40 or 1 space module code 044 41).
2
Blinking clock symbol = set time of day
Constant hand symbol = manual override
Actual day of the week or program day
Segment display of the existing program
switching time, copying programs
1
2
3
4
5
Technical data
036 84
Supply voltage:
230V~
Frequency:
50/60 Hz
Consumption:
ca. 0,6W
1 changeover contact 10A 250V~µ cos ϕ = 1
Contact rating:
Parallel compensation:
not allowed
accuracy:
±2,5s/d
Terminal capacity:
single strand
1 to 4 mm
Program pictures:
28
Battery reserve:
20h
Storage ambient:
-10°C to +60°C
Working ambient:
0°C to +55°C
24
18
6
3
12
Pr
C
1. Starting
Reset 1
Switching programs remain
Press
together
Reset 2
Switching programs deleted
Press
together
Hold
, and let
Hold
for 5 seconds, then let free
Operating instructions
036 85
036 86
120V~
24V~
multi strand
2
0,5 to 2,5 mm
State of contact:
= On /
= Off
Real time, set on time or set off time
Symbol for program input or interrogation
Accepting the on and off times,
manual switching
Setting days, hours, minutes, on and off times
free
GB
®
94 41 78
12V DC
2
24
18
6
1
12
24
18
6
1
12

Advertisement

loading

Summary of Contents for LEGRAND Lexic RondoRex w21

  • Page 1 Time switch Operating instructions RondoRex w21 ® NT 29 17 54 02 Technical data 036 84 036 85 036 86 94 41 78 Supply voltage: 230V~ 120V~ 24V~ 12V DC Frequency: 50/60 Hz Consumption: ca. 0,6W 1 changeover contact 10A 250V~µ cos ϕ = 1 Contact rating: Parallel compensation: not allowed...
  • Page 2 1. Weekday and Time setting 2. Setting switching times Press until blinks Press 4x, switch time, Pr symbol blinks Press to set weekday 1. on time setting 1 = Monday Setting advances in minutes 2 = Tuesday 3 = Wednesday Press once = 1 minute 4 = Thursday Hold = 15 minutes steps...