Product Specifications - Vessel STAT CLEAN G2-E Instruction Manual

Static eraser gun
Table of Contents

Advertisement

■Product Specifications

ION/BEAM GUN
Model
Ion generation method
Impressed voltage
Input voltage
Power consumption
Dimensions
Weight
Air consumption
Ozone generation
Warning output
Protective function
Working ambient
temperature / humidity
Storage temperature/humidity
Distance from target object
Static electricity removal time
Ion balance
Material
Accessories
AC Adapter No.AD24-ITC
Rated input voltage
Rated output voltage
Working ambient
temperature / humidity
Cable length
Weight
*The measurement values were obtained on the VESSEL measurement environment and conditions,
so error could be induced depending on the operation environment.
Replaceable Parts : Electrode Needle GN-H
Options : Tube-Fitting Nozzle G-7THN / AC Adapter AD24-ITC /
Speed Controller G-7SC G-7DR / Electrode Needle Replacement Screwdriver G-7DR
:No. G2-E
:High voltage AC corona discharge
:4.5kVAC(P-P) approx.
:24VDC±5%
:100mA (TYP.)
:L148 x H157 x W44(mm)
:260g
:0.1~0.6MPa
:0.05ppm or less (Measured at 50mm)
:High voltage alarm output stop (Red LED)
:Current fuse (0.5 A on the board)
:5~40˚C 35~65%RH (No dew condensation or freezing)
:0~60˚C 35~85%RH (No dew condensation or freezing)
:50~300mm (Installation:Indoor, non-hazardous area)
:Refer to the table on the page 5.
:Within±10V (At 0.3MPa and 150mm from the target)
:Casing:Fire retardant polycarbonate and elastomer
:Hook:SUS
:Electrode Needle:Tungsten
:Instruction Manual, AC Adapter
:100-240VAC(50/60Hz)
:24VDC 0.75A
:0~40˚C 5~95%RH(No dew condensation or freezing)
:DC output cable:2.5m approx. AC input cable:1.8m approx.
:about 170g
4
0.4A(TYP.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents