Pentair Pool Products IntelliChlor PC100 Installation And User Manual page 5

Table of Contents

Advertisement

WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
For information about the Virginia Graeme Baker Pool and Spa Safety
Act, contact the Consumer Product Safety Commission at (301) 504-
7908 or visit www.cpsc.gov.
NOTE: Always turn off all power to the pool pump before installing the
cover or working on any suction outlet.
When mixing acid with water, ALWAYS ADD ACID TO WATER.
NEVER ADD WATER TO ACID.
Do not operate electrolytic cell without proper flow or water
circulation. A build-up of flammable gases will result in
hazardous conditions.
When using IntelliChlor with an IntelliTouch system, it is recom-
mended to wire the IntelliChlor Power Center to the pump side of
the relay located in the IntelliTouch Load Center. This wiring
method does not require a ground fault circuit-interrupter (GFCI)
to protect the circuit. A green colored terminal (or a wire connec-
tor marked "G", "GR", "Ground" or "Grounding") is provided within
the terminal compartment in the Power Center transformer
enclosure. To reduce risk of electric shock, connect this terminal
or connector to the grounding terminal of your electric service or
supply panel with a conductor equivalent in size to the circuit
conductors supplying this equipment. The power supply must be
interconnected with pool pump motor power source. This insures
the IntelliChlor chlorinator and pool pump will switch on and off
together.
Use of chemicals other than those recommended may be
hazardous. Follow the Chemical Manufacturer's Instructions.
Install the IntelliChlor unit a minimum of two (2) feet from the
heater outlet.
It is recommended to install a Pentair Water Pool and Spa®
two ( 2) inch CHECK VALVE (P/N 263042) between the input
side of the IntelliChlor cell and the main heater output pipe.
Water temperature in excess of 100° F (37.7° C) may be hazardous to
your health. Prolonged immersion in hot water may induce
hyperthermia. Hyperthermia occurs when the internal temperature of
the body reaches a level several degrees above normal body
temperature of 98.6° F (37° C.). Effects of hyperthermia include: (1)
Unawareness of impending danger. (2) Failure to perceive heat. (3)
Failure to recognize the need to leave the spa. (4) Physical inability to
exit the spa. (5) Fetal damage in pregnant women. (6)
Unconsciousness resulting in danger of drowning. The use of alcohol,
drugs, or medication can greatly increase the risk of fatal
hyperthermia in hot tubs and spas.
IntelliChlor Power Center Installation Guide
iii

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellichlor ic20Intellichlor ic40Intellichlor ic60

Table of Contents