WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Never operate the IntelliChlor Electronic Chlorine Generator (IECG)
without proper flow or water circulation. A build-up of flammable
gases will result in hazardous conditions. Operate unit with
minimum flow of 25 gpm. For high flow applications, use a bypass
loop.
Only use pipe couplings that meet Schedule 80, maximum pressure
150 psi at 70° F.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION:
Always disconnect power to the IntelliChlor salt chlorine generator
at the circuit breaker before servicing. Failure to do so could result
in death or serious injury to service person, pool users or others
due to electric shock.
IntelliChlor Electronic Chlorine Generator (IECG) is for use with
permanently-installed pools and may also be used with hot tubs
and spas if so marked. Do not use with storable pools. A
permanently installed pool is constructed in or on the ground or in
a building such that it cannot be readily disassembled for storage.
A storable pool is constructed so that it is capable of being readily
dissembled for storage and reassembled to its original integrity.
The IECG Power Centers must be interconnected with the pool
pump motor power source. This ensures the IECG and pool pump
will switch on and off together.
When mixing acid with water, ALWAYS ADD ACID TO WATER.
NEVER ADD WATER TO ACID.
Use of chemicals other than those recommended may be hazard-
ous. Follow the Chemical Manufacturer's Instructions.
To reduce the risk of electric shock, install IntelliChlor Electronic
Chlorine Generator (IECG) a minimum of five (5) feet away from
the inside wall of the pool.
Install the IECG a minimum of three (3) feet away from the heater
outlet. Allow ample access to the IntelliChlor control panel buttons
and the IntelliChlor Power Center.
It is recommended to install a Pentair two (3) inch CHECK VALVE
(P/N 263060) between the input side of the IECG and the main
heater output pipe.
A solid copper, bonding conductor not smaller than No. 8 AWG
(8.4 mm) should be connected to all metal parts of the swimming
pool, spa, or hot tub structure and to all electrical equipment,
metal conduit, and metal piping.