Pentair Pool Products IntelliChlor PC100 Installation And User Manual page 10

Table of Contents

Advertisement

5
Connect AC Power to the IntelliChlor
6.
Use 12-14 AWG three conductor insulated wire for the main AC power
connection. Connect the Power Center to pool pump AC power source. The
Power Center should be connected to the pump motor switch or automatic timer.
For system wiring information, see page 6.
7.
Attach incoming GROUND wire to the ground lug inside the Power Center.
8.
Earth Bonding (Grounding): Connect the earth wire to the GROUND BONDING
LUG located on the bottom of the Power Center enclosure. Earth bonding is
necessary to ensure personal safety and safety of equipment.
IMPORTANT: A number 8-gauge (8.4 mm) wire is recommended when connecting
the power supply to a Permanent Earth Ground connection that is acceptable to
the local inspection authority. Attach the bonding point located on bottom of the
Power Center to a Common Earth Bonding Point. Do not use the IntelliChlor as
the Common Bonding Point. Each piece of non-chlorinator pool equipment
requiring a ground should be bonded to the Common Approved Earth Bonding
Point. Never ground pool pump to Power Center.
9.
Reinstall the Power Center cover and secure with the cover screw.
10. The Power Center installation is complete. For IntelliChlor operating information,
refer to the IntelliChlor User's Guide (P/N 520589).
Connect incoming ground
wire to GROUND lug
Attach incoming power
wires (12-14 AWG 3-wire)
to Power Center
AC power wires
Conduit knockout
for AC power cable
IntelliChlor Power Center Installation Guide
source
®
Power Center
Ground bonding lug

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellichlor ic20Intellichlor ic40Intellichlor ic60

Table of Contents