PR electronics Loop Link 5909 Manual

Usb communications interface
Hide thumbs Also See for Loop Link 5909:

Advertisement

5 9 0 9
U S B C o m m u n i c a t i o n s
I n t e r f a c e
N o . 5 9 0 9 V 1 0 1 - I N ( 1 0 0 7 )
F r o m s e r . n o . 0 4 0 6 5 4 0 0 1
S I G N A L S T H E B E S T
USB COMMUNICATIONS INTERFACE
LOOP LINK 5909
Contents
Warnings............................................................................. . 16
Safety.instructions. . ............................................................. . 17
EC.Declaration.of.Conformity............................................. . 19
Application.......................................................................... . 20
Technical.characteristics..................................................... . 20
Installation........................................................................... . 20
System.requirements.......................................................... . 20
Installation.of.PReset.......................................................... . 20
. Special.instructions.for.Windows
Connection.of.PR.modules.using.a.modular.connector. . ... . 28
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au
www.omniinstruments.com.au
®
.98SE,.ME.and.XP.. 20
®
.98.SE.and.ME......... . 21
®
.XP............................ . 22
®
.Vista.................. . 23.
UK / Europe Office
Tel: +44 (0)845 9000 601
Fax: +44 (0)845 9000 602
info@omniinstruments.co.uk
www.omniinstruments.co.uk
USA / Canada Office
Tel +1-866-849-3441
Fax +1-866-628-8055
info@omniinstruments.net
www.omniinstruments.net
15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Loop Link 5909 and is the answer not in the manual?

Questions and answers

Summary of Contents for PR electronics Loop Link 5909

  • Page 1 USB COMMUNICATIONS INTERFACE LOOP LINK 5909 Contents Warnings................16 Safety.instructions..............17 EC.Declaration.of.Conformity..........19 Application................20 Technical.characteristics............20 Installation................20 System.requirements............20 Installation.of.PReset............20 Installation.of.USB.drivers.for.Windows ® .98SE,.ME.and.XP.. 20 . Special.instructions.for.Windows ®...
  • Page 2 Should.there.be.any.doubt.as.to.the.correct.handling.of.the.module,.please. can.occur..It.must.only.be.connected.to.the.programming.unit. INSTAL- contact.your.local.distributor.or,.alternatively, 5909.by.way.of.the.attached.communication.cable. LATION PR electronics A/S, Lerbakken 10, DK-8410 Rønde tlf: +45 86 37 26 77 SYMBOL IDENTIFICATION: Triangle with an exclamation mark: Warning/demand. Potentially.lethal.situations.. The CE mark proves.the.compliance.of.the.module.with.the. requirements.of.the.EU.directives.. The.double insulation symbol shows.that.the.module.is. protected.by.double.or.reinforced.insulation.
  • Page 3 EC DECLARATION OF CONFORMITY PROGRAMMING: During.programming,.the.measuring.and.connection.of.external.voltages.must. As.manufacturer be.carried.out.according.to.the.specifications.of.this.manual.and.the.manual.for. the.unit.to.be.programmed.. PR electronics A/S The.technician.must.use.tools.and.instruments.that.are.safe.to.use. Lerbakken 10 DK-8410 Rønde NORMAL OPERATION: Operators.are.only.allowed.to.adjust.and.operate.modules.that.are.safely.fixed. hereby.declares.that.the.following.product:. in.panels,.etc.,.thus.avoiding.the.danger.of.personal.injury.and.damage..This. Type: 5909 means.there.is.no.electrical.shock.hazard,.and.the.module.is.easily.accessible. Name: Loop Link CLEANING: is.in.conformity.with.the.following.directives.and.standards: When.disconnected,.the.module.may.be.cleaned.with.a.cloth.moistened.with. distilled.water. The.EMC.Directive.2004/108//EC.and.later.amendments EN 61326-1 LIABILITY: To.the.extent.that.the.instructions.in.this.manual.are.not.strictly.observed,.the. . For.specification.of.the.acceptable.EMC.performance.level,.refer.to.the. customer.cannot.advance.a.demand.against.PR.electronics.A/S.that.would.
  • Page 4 Application: 1. Connect Loop Link 5909 to the USB port of the PC. 2. After a short while, the guide ”New hardware found” will be shown. Loop.Link.5909.is.a.USB.communications.interface.for.configuration. This guide will help you through the installation of the first USB and.monitoring.of.PR.electronics’.PC-programmable.modules..The.USB.
  • Page 5 1. You must say [No, not this time] to the following dialogue: Install.the.USB.drivers.while.the.PReset.CD.is.still.in.the.drive,.i.e..immediately. after.the.PReset.installation.. 1. Connect Loop Link 5909 to the USB port of the PC. 2. After a short while, the ”Found New Hardware Wizard” will be shown. This guide will help you through the installation of the USB driver.
  • Page 6 5. Click [Close] in the following dialogue: 7. Click [Browse my computer for driver software] in the following dialogue: 6. Open the Device Manager and right click [Unknown device]. Then 8. You will see the following dialogue where the path ”CD-ROM drive:\ left click [Update Driver Software].
  • Page 7 Configuration of USB communication in PReset: 9. Click [Install this driver software anyway] in the following dialogue: 1. Start the PReset program and choose [Functions] [Set COM port], and the ”Options” window is shown on screen. 2. Select ”Next 5909”. PReset now selects a COM port which will be linked with the USB port to which Loop Link is connected.
  • Page 8 Displays Connection of PR modules using EZ-Mini-Hooks: Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and Receiving difference measurement functions for programming via Equipment Disconnect PReset software. +Vsupply Yellow Input...

Table of Contents