8) Fuzzy washing function (weight-sensing)
● After fi nishing initial water supply, when the fall of the water level needs supplementary water supply,
Sensing function perceives the weight with the supplementary water supply numbers and starts to
work. Under the course of Cotton, or Coloureds, if the supplementary water supply numbers become
over 2 times the function is going at default condition ( high water level ), if 1 time that is going at
middle level, if 0 below low water level, heating hours and rinse hours depend on the above data.
ECO PRE mode is selected, the process going on at default condition.
High
Middle
Low
After sensing weight, above hours is decreased from above default hours
9) Bubble - detecting function
At the each condition of washing&dehydrating , rinse&dehydrating , hydrating, bubble -detecting function
works, this function works 5times normally, if the function detects bubbles at 6 times , the bubble-detecting function
stops and go on to the next process.
The bubble-detecting function during washing & dehydrating to rinse & dehydrating
after 2 times instant dehydrating and before main dehydrating, if the water level is under 24.50KHZ,
Bubble
→ Detecting function thinks there are bubbles and add the bubbles-removing rinse, needing
hours are above hours and 8 Min 40 sec.
→ The bubble-detecting function during single hydrating process
after 2 times instant dehydrating and before main dehydrating , if the water level is 24.50KHZ below or
during main dehydrating, water level data is 24.50KHZ below Bubble-detecting function thinks there are
bubbles and add the bubbles-removing rinse 1 times, needing hours are above hours and 5 min 50 sec.
Bubble-detecting function operating process
18 sec
laundry scattering
draining &reverse
50 sec
All manuals and user guides at all-guides.com
Washing hours
Cotton
Default
Default-20 min
Default-30 min
unbalance
detecting range
11
Coloureds
Default
Default-10min
Default-15min
500rpm
220rpm
bubble detection
(default water level 24.50KHZ below)
Rinse water level
Default
23.80KHZ
24.10KHZ