CONTRAST ADJUSTMENT (NTSC/PAL VIDEO)
Measuring Instruments
Card (Slot)
Test Points
Adjustment Points
Notes:
Ensure that the output waveforms from the NTSC/
PAL Video Input Cards are normal before proceeding
to the following adjustments.
Perform the following adjustments after completing
the 1080/60i signal Contrast Adjustment.
Set the CONTRAST data in the Setup Menu to "00".
The SO value (see the description of the HDTV
Contrast Adjustment) becomes the reference value
for the following adjustments. When this data is
changed, it is required to re-adjust the data of all of
the adjustment signals (HDTV, SDTV and NTSC/PAL).
When re-adjusting the 1080/60i signal, use the SI. (For
the adjustment of the 1080/60i signal, use the
Component/RGB Input Card.)
(1) Apply the NTSC crosshatch signal to INPUT C (Terminal
VIDEO1 on the NTSC/PAL Video Input Card).
(2) Set the CONTRAST potentiometer on the front panel to
the center click position.
(3) Connect the oscilloscope across TP-47G and TP-GND.
(4) Adjust SA01 in the Service Menu to set the voltage
amplitude <A> in the figure on the right to the voltage shown
in the Table 3.
(5) Vary the adjustment signal and adjustment data, and re-
perform adjustments in steps 1 to 4 above (see Table 3).
1-50 (No. 52152)
Signal generator (Crosshatch signal)
Oscilloscope
NTSC/PAL Video Input Card (Slot 2)
TP-47G [CRT SOCKET PWB]
TP-GND [CRT SOCKET PWB]
S*01 (Contrast) [Service Menu]
(V. sync)
1 Vertical interval
<A>
Adjustment Signal Adjustment Data Adjustment Voltage <A>
NTSC (VIDEO)
SA01
PAL (VIDEO)
SC01
Table 3
36 V ± 2 V
36 V ± 2 V