MP SERIES - PUMP SPECIFICATIONS
U.S. Measurements
Max.
Flow
Model
GPM
MP4120
8.9
MP4124
12.8
MP4135
13.5
MP4130
15.4
MP4130HK
15.4
MP4126
17.9
Metric Measurements
Max.
Flow
Model
L/min
MP4120
33.8
MP4124
48.6
MP4135
51.2
MP4130
58.2
MP4130HK
58.2
MP4126
67.7
Consult the factory for special requirements that must be met if the
pump is to operate beyond one or more of the limits specified above.
Horsepower Ratings:
We recommend a 1.15 service factor be specified when selecting an electric motor as the power source.
To compute electric motor horsepower required, use the following formula:
The formula to determine the horsepower required for a gas engine is: HP = (GPM X PSI) / 1150.
For the Application of a Hydraulic Motor:
To Determine the Torque of a Hydraulic Motor -- (GPM x PSI x 36.77) / RPM = Torque (in-lbs)
Calculating RPM / GPM of Pump:
A pump must be connected to an electric motor or gas or diesel engine with the correct ratio of pulleys
and belts to attain the required speed and GPM. The use of a Variable Frequency Drive (VFD) may also
be used to control the RPM of a properly sized electric motor when variable flows are required.
(Max. Pump RPM / Rated Pump GPM) x Required Pump GPM = Required Pump RPM
To calculate a pulley diameter one (1) pulley diameter and the required pump RPM must be known:
(Pump RPM x Pump Pulley Diameter) / Motor RPM = Motor Pulley Diameter
(Motor RPM x Motor Pulley Diameter) / Pump RPM = Pump Pulley Diameter
Common Specifications:
Inlet Pressure ........................ 145 PSI (10 Bar)
Crankshaft Diameter.............. 1.10" (28 mm)
Crankcase Oil Capacity ......... 33.8 fl. oz. (1 L)
Inlet Ports .............................. (2) 1" NPT
Discharge Ports ..................... (2) 3/4" NPT
Stroke (except MP4126) ........ 1.02" (26 mm)
Stroke (MP4126 only) ............ 1.18" (30 mm)
Weight ................................... 66 lbs (30 kg)
Shaft Rotation............Top of Pulley Toward Fluid End
Max. Pres-
Max.
sure
Speed
PSI
RPM
3625
1450
2610
1450
1885
1100
1600*
1100
1600
1100
1600
1100
Max. Pres-
Max.
sure
Speed
bar
RPM
250
1450
180
1450
130
1100
110*
1100
110
1100
110
1100
Power
Max.
Required
Temperature
HP
°F
23.1
160
24
160
18.2
160
17.6
160
17.6
195
20.4
160
Power
Max.
Required
Temperature
kW
°C
17.2
70
17.9
70
13.6
70
13.1
70
13.1
90
15.2
70
Materials Used for MP Pumps:
Manifold ........ Aluminum Bronze
Plungers ....... Solid Ceramic Oxide
Valves ........... High Grade Stainless Steel
Seals............. Nitrile with Fabric Reinforcing
Gear End ...... Spheroidal Cast Iron
3
Plunger
NPSH Re-
Diameter
quired
in
Ft-Head
0.787
24.6
0.945
27.9
1.1
29.5
1.18
29.5
1.18
N/A
1.18
N/A
*Intermittent rating of 2000 PSI
Plunger
NPSH Re-
Diameter
quired
mm
mWs
20
7.5
24
8.5
28
9
30
9
30
N/A
30
N/A
*Intermittent rating of 140 bar
HP = (GPM X PSI) / 1450.