Heating Characteristic
[Condition] Room temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
A) Indoor unit capacity: Heating (2.0 + 2.5 + 4.2), CS-TZ20TKEW + CS-TZ25TKEW + CS-TZ42TKEW
35.800
34.800
33.800
32.800
31.800
30.800
29.800
28.800
27.800
26.800
25.800
-16
10.000
9.600
9.200
8.800
8.400
8.000
-16
2.400
2.350
2.300
2.250
2.200
2.150
2.100
2.050
2.000
1.950
1.900
-16
-14
-12
-10
-8
Outdoor Air Temperature (°C)
-14 -12
-10
-8
-14 -12
-10
-8
Outdoor Air Temperature (°C)
TZ20TKEW
-6
-4
-2
0
-6
-4
-2
0
Outdoor Air Temperature (°C)
-6
-4
-2
0
82
TZ25TKEW
TZ42TKEW
2
4
6
8
2
4
6
8
2
4
6
8
10
12
10
12
10
12