Kenmore 625.34854 Owner's Manual page 23

Sears water system user manual
Table of Contents

Advertisement

SECTION
5
SERVICE TECH INFORMATION
5A.
TROUBLESHOOTING
MANUAL
ADVANCE
REGENERATION
CHECK
This check
verifies
proper
operation
of the valve
motor,
brine
tank
fill, brine
draw,
regeneration
flow rates,
and other
controller
functions.
Always
make
the
initial
checks,
and
the
manual
initiated
diagnostics.
NOTES:
The face plate
display
must show
a steady
time
(not
flashing).
If an Error
code
shows,
first
press
the #1 SELECT button
to enter
the diagnostic
display.
lo
Press
the ON/OFF-HOLD
button
and
hold
in
for
3 seconds.
RECHARGE
NOW
and
FILL
begin
to flash
as the
softener
enters
the
fill
cycle
of regeneration.
When
FILL is on steady,
remove
the
brinewell
cover
and,
using
a
flashlight,
observe
fill water
entering
the tank.
a.
If
water
does
not
enter
the
tank,
look
for an
obstructed
nozzle,
venturi,
fill flow
plug,
brine
tubing,
or brine
valve
riser
pipe.
CYCLE
FLOW
RATES
(GALLONS
PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
"_
.19 (.7 liters)
BRINE
RINSE
I
.12 (,45 liters)
BACKWASH
(flow to drain)
2.0 (7.6 liters)
FAST RINSE
2.0 (7.6 liters)
o
After observing
fill, press
the ON/OFF-HOLD
button
to move
the
softener
into
brining.
A
slow
flow
of water
to the
drain
will
begin.
Verify
brine
draw
from
the
brine
tank
by
shining
a flashlight
into
the
brinewell
and
observing
a noticeable
drop
in the liquid
level.
NOTE:
Be sure
a salt
bridge
is not
preventing
water
with
salt
contact.
ao
If the softener
does
not
draw
brine •
• nozzle
and/or
venturi
dirty
or defective.
• nozzle
and
venturi
not seated
properly
on
gasket.
• restricted
drain
(check
drain
fitting
and
hose).
• defective
nozzle
and
venturi
seal.
• other
inner
valve
defect
(rotor
seal,
rotor
&
disc, wave
washer,
etc.).
NOTE:
If
water
system
pressure
is
low,
an
elevated
drain
hose
may
cause
back
pressure,
stopping
brine
draw.
3.
Again
press
ON/OFF-HOLD
to
move
the
softener
into backwash.
Look
for a fast flow of
water
from
the
drain
hose.
ao
o
o
An obstructed
flow
indicates
a plugged
top
distributor,
backwash
flow plug,
or drain
hose.
Press
ON/OFF-HOLD
to move
the
softener
into fast rinse.
Again
look
for a fast drain
flow.
Allow
the softener
to rinse
for a few minutes
to
flush out any brine
that may remain
in the resin
tank
from
the brining
cycle
test.
To
return
the
softener
to
service,
press
ON/OFF-HOLD.
BRINE VALVE
FLOAT 5ETTIN(_
_t
Float
__""-
Stop
1F
FREEBOARD
MEASUREMENT
(Distance from top of resin tank to top of
resin
T
FREEBOARD
7"-11"
1
Resin Tank
Resin Bed

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

625.34855625.3485400625.3485500

Table of Contents