Helpful - Kenmore 625.34854 Owner's Manual

Sears water system user manual
Table of Contents

Advertisement

SECTION
3
CARE OF YOUR SOFTENER
3D.
HELPFUL
HINTS CHECKLIST
... TO HELP YOU SAVE MONEY
If your water
softener
fails to work,
make the following
easy checks. Often, you will find what's
wrong
yourself
and you won't
have to call and wait for service.
If, after making
the checks, your
softener
still
does not work right,
call your Sears Service
Department.
NOTE:
1. Also read
ERROR CODE,
page
11.
2. If an error code is not dispIayed,
press and holdthe
#1 SELECT button
until (example:
000- -) shows
in the display.
Then,
press the #1 SELECT
again
and hold until a flashing
AR code appears.
It must
show AR31.
If AR 17, 22, 39 or 60 shows,
the face plate computer
is working
on incorrect
input
and
would
probably
be the cause of the problem.
To set AR31, press either the UP [] or DOWN
{_)utton.
When AR31 shows,
press the # 1SELECT to return
a flashing
12:00 AM display.
Reset the present
time,
hardness
number
and recharge
time, pages
6 and 7.
PROBLEM
CAUSE
CORRECTION
NO SOFT WATER
No salt (or salt bridged ) in the storage
tank
Transfomer
unplugged
at the wall outlet,
or
power cable leads loose, fuse blown,
circuit
breaker
popped,
or circuit switched
off.
Manual
bypass
valve(s)
in bypass
position
Dirty, plugged
or damaged
nozzle
& venturi
Valve drain hose plugged
WATER
HARD
Hardness
number
setting
too low
SOMETIMES
Using hot water when softener
is
regenerating
Increase
in the grains of hardness
in your
water
supply
Refill with salt, or break the salt bridge
(page 15). Press
ON/OFF-HOLD
(RECHARGE
NOW)
button and hold for 3
seconds
to start a regeneration
(see page
10).
Check for loss of power due to any of
these
and correct.
With the power back
on, look at the time display
and read
PROGRAM
MEMORY,
page 11.
Look at FIG. 12 on page 19. Move the
stem in a single valve to service.
In a
3-valve
bypass,
open the inlet and outlet
valves,
and be sure to fully close the
bypass
valve.
Take apart and clean or replace
damaged
parts (see page 16).
The drain hose must not have kinks,
sharp
bends, or be raised too high above the
softener
(see page 16 in your installation
manual).
Press and release
the SELECT
button
until HARDNESS
shows
in the display.
Read the hardness
number
in the display
and be sure the same
grains per gallon
number
is shown
on your water
analysis
report.
See page 7 to reset. Press and
release the SELECT
button
until the
present time shows in the display.
Avoid using hot water
during this time
because
the water heater refills with hard
water
(see Automatic
Bypass,
page 14).
Ask your Sears retail or catalog
store for a
new water
analysis.
Then make
a new
hardness
number
setting
(page 7).
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

625.34855625.3485400625.3485500

Table of Contents