3. Use this pump only for backup sump pump duty in a res-
idential appfication. It is not designed as a primary sump
pump.
4 la -- lHa o.
Vo ¢. Can c a €
or
I
h
fatal electrical shock. Do not plug in or unplug battery
charger
while standing
on a wet floor or in water. Be sure
one hand is free when pluggingin orunplugging charger.
If basement
floor is wet, disconnect
power
to basement
before walking on floor.
5. Do not lift pump by electrical cord,
6. Pump water only with this pump.
7. Do not run pump dry. To do so will damage seals and can
cause lealdng and property damage.
8. Pump is permanently lubricated at the factory. Do not try
to lubricate
it!
9.Keep
battery
charger
and battery
box in a dry, cool, well
---ventilated
area.
lO.To
avoid danger
of fire or explosion,
keep sparks
and
" flame away from battery.
11. [ ,AWARNING IBattery
acid is corrosive.
Do not spill on
skin, clothing,
or battery
charger.
Wear
eye protection
when
working
on battery.
12. Maximum
vertical
pumping
distance
is 15 feet.
13. Make sure sump is clear of debris.
BASIC TOOLS
AND MATERIALS
NEEDED
Pipe Wrenches
Screwdriver
Hacksaw
1-1/4" Check
Valve
Adjustable-Wrench
Teflon Tape
Knife
12-volt Battery
GENERAL
INFORMATION
The Battery-Powered
Back-up Sump Pump is not a substitute
for your primary
sump
pump.
It is designed
as a backup
pump
to pinch-hit
for your primary
sump
pump
during
a
power
outage
or other
problem
which
prevents
normal
op-
eration.
Do not use it to pump
flammable
fiquids
or chemi-
cals.
Keep battery
charger
dry and protected
from damage.
In an
emergency
(such
as an extended
power
outage)
which
depletes
the system battery,
your automobile
battery
-may
be temporarily
substituted.
Be sure to replace
the sys-
tem battery
as soon as possible.
CHARGER
OPERATION
Backup
pump
will start automatically
when
sump
water
level rises far enough
to trip float switch.
After a delay, of
about 4 seconds,
alai'm will sound.
Silence
alarm by pushing
ALARM TEST/RESET button.
In normal
(switch
actuated)
op-
eration,
alarm is locked
out until about 4 seconds
after float
switch
has dropped
to OFF position;
cycle
can then begin
again.
Test
alarm
by pushing
ALARM TEST/RESET
button
when
alarm is not sounding.
Alarm will then sound
as long as but-
ton is held down.
Pushing
ALARM TEST/RESET
button
to
test alarm
overrides
lockout,
so alarm
can be tested at any
time.
If alarm sounds, check operation of primary pump, which
may need service. If battery backup operation is due to a
power outage, alarm will sound, but no service is likely to
be req_,ed to primary pump.
Battery charger has capacity to run pump and charge battery
at the same time as long as power to the charger is not in-
terrupted.
If power to charger circuit is interrupted,
the
length of time that the backup pump will run depends on
the Ampere-hour capacity of the battery used.
Extended periods of operation (for example, during an ex-
tended power outage) may exhaust the battery. However,
once the load is removed, usually it will self-regenerate far
enough to allow the charger to start. The battery charger will
begin charging the battery as long as the battery has a charge
of at least 1/2 volt, and power is available to the charger.
After power is restored, charger will automatically re-charge
battery fully in about six hours.
NOTICE: Some trouble conditions will cause the alarm to
sound. See chart below for causes and action:
PROBLEM
ACTION
Back-up pump
has run
Push 'Reset'.
Check main pump.
Power out more
than
Disconnect
charger
from battery.
24 hours
Call power
company.
Continuous
charging
Disconnect
charger
from battery.
more
than 24 hours
Check
for defective
battery.
Loose connection
or
Disconnect
charger
from battery.
no power
to charger
Check
plug, receptacle,
and
power
at main breaker.
After restoring
power
or replacing
battery,
alarm
can be
reset.
• Purchase l ocal.
For small/shallow
sump pits install
as illustrated
above.
Installation
Kit 2785
includes the necessary clamps and supportpad needed forthisinstallation.
Follow
other
instructions
in the owner's
manual
Figure I - Installation
in small or shallow sumps
- use Kit 2785; sump diameter
is exaggerated
for clarity.

Advertisement