ELECTRICAL REQUIREMENTS

The Ultra-Aire 100V plugs into a common grounded 115 VAC outlet. The device draws 5.9 Amps at 80°F
and 60% RH. Locate the dehumidifier in an area where the cord's length (9') easily reaches a 115 VAC
electrical outlet with a minimum of 15 Amp circuit capacity. If used in an area that may become wet, a GFCI
protected circuit is recommended. Consult local electrical codes for further information.
Ultra-Aire offers a variety of control devices for use with the Ultra-Aire 100V. The control is to be located
remotely from the dehumidifier and placed in the space to be conditioned. A low voltage (24 Volt) control MUST
be used with the Ultra-Aire 100V and MUST be connected with low voltage (18-22 gauge) thermostat wire.
WARNING!
THE REMOTE CONTROLS OF THE ULTRA-AIRE 100V ARE POWERED BY A LOW VOLTAGE CIRCUIT
(24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
CAUTION!
DO NOT ALLOW THE YELLOW LEAD TO CONTACT THE RED OR WHITE LEAD ON THE
ULTRA-AIRE 100V OR DAMAGE TO THE TRANSFORMER WILL RESULT.
CAUTION!
SOME OF THE CONTROL WIRES LEAVING THE ULTRA-AIRE 100V MAY NOT BE USED WITH
CERTAIN CONTROLS AND SHOULD BE LEFT UNCONNECTED WITH WIRE NUTS TAPED ONTO
THE STRIPPED ENDS FOR SAFETY.
Electrical Precautions
• Do not install the control where it may not accurately sense the relative humidity such as near HVAC
supply registers, near exterior doors, on an outside wall, near a window, or near a water source.
• The control wires leaving the Ultra-Aire 100V and the control are numbered and color-coded to
prevent confusion.
• Be sure to consult the
electrical schematic in the
CONTROLS Section
(page 19) of this manual or
inside the access panel of
the Ultra-Aire 100V
before making control
connections.
8
Ultra-Aire 100V Installation Instructions