Recommended Multiple HVAC Systems Installation

The Ultra-Aire 100V can be installed on multiple HVAC systems. Dehumidified air will be provided to both
HVAC systems for distribution throughout the structure.
• Backdraft dampers are required in the supply ducts.
• DO NOT locate the return in a bathroom or kitchen.
• One control will service both HVAC zones. Control should be located remotely from the dehumidifiers and
placed in a central location.
• HVAC systems should be in close proximity for optimal air flow.
• For multiple systems, contact Technical Support at 1-800-533-7533.
CAUTION!
DO NOT CONNECT WITH A STATIC PRESSURE GREATER THAN OR EQUAL TO +0.5 WG.
CONTACT TECHNICAL SUPPORT AT 1-800-533-7533 FOR ADDITIONAL DETAILS.
Dedicated Ultra-Aire Return to Multiple HVAC Systems
14
Ultra-Aire 100V Installation Instructions
Indoor
Air Return
Backdraft
Damper
Ultra-Aire
Supply
Backdraft
Damper
HVAC
Supply
DUCTING TO HVAC SYSTEMS
Second Air Handler
HVAC
Supply
First Air Handler
Motorized
Damper
Fresh Air
Intake
(Optional)
HVAC Return
HVAC Return
www.Ultra-Aire.com | 1-800-533-7533