Pinless lcd moisture meter with tricolor bargraph (28 pages)
Summary of Contents for General P16181HP
Page 1
VGA RESOLUTION PROBE USER’S MANUAL P16181HP P16182HP P16183HP 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
VGA (640 x 480 pixel) resolution. The only difference among the three probes is their length. The P16181HP is 1m (3.3 ft.) long, the P16182HP is 2m (6.6 ft.) long, and the P16183HP is 3m (9.8 ft.) long.
Setup Instructions and Operating Instructions. Fig. 1. The controls and key structures of the P16181HP/P16182HP/P16183HP 1. Probe 2. Stainless steel camera head containing four forward-facing LEDs and two side-facing LEDs 3.
To secure the connection, push the collar forward and turn it clockwise until tight. OPERATING INSTRUCTIONS For general guidelines on using the probe as an inspection tool, refer to the Operating Instructions section of the user’s manual for your borescope or borescope console.
USING THE THREE CONTROL BUTTONS To boost the intensity of the four LEDs normally providing camera lighting, press the button. Doing so lights a red LED behind the button and improves the brightness of video and images, as shown below. BEFORE BOOST AFTER BOOST This feature can help you cope with very low-light conditions.
You can also use the anti-reflection function to remove glare created by the probe’s mirrored viewing tip (see the next section of this manual for installation and alignment instructions). The pair of images below illustrates the net positive effect. MIRRORED VIEW MIRRORED VIEW WITHOUT ANTI-REFLECTION WITH ANTI-REFLECTION...
7. Secure the tip with the thumb and forefinger of one hand and use your other hand to turn the alignment ring clockwise. Keep turning the ring until its leading edge contacts the mirrored viewing tip, locking it in place. The pair of figures below illustrate the incorrect (left) and correct (right) orientation of the mirror with respect to the LEDs.
OPERATING & MAINTENANCE TIPS The probe is flexible to make it easy for you to inspect hard-to-reach areas. Never insert or bend it by force, and never over-bend any part of the probe. Specifically: • Do not bend the last 1 to 2 inches (25 to 50mm) of the probe by more than 70°...
General will repair or replace this instrument if, after examination, the company determines it to be defective in material or workmanship. This warranty does not apply to damages that General determines to be from an attempted repair by non-authorized personnel or misuse, alterations, normal wear and tear, or accidental damage.
RETURN FOR REPAIR POLICY Every effort has been made to provide you with a reliable product of superior quality. However, in the event your instrument requires repair, please contact our Customer Service to obtain an RGA (Return Goods Authorization) number before forwarding the unit via prepaid freight to the attention of our Service Center at this address: Remember to include a copy of your proof of purchase, your return address,...