5. Operating the Cobra 3.1
The fog output can now be adjusted from 0 - 100% via the DMX-desk.
If you also want to change the Mode (Impulse, Extended, Flood, Continuous) at the
desk, the Personality has to be changed to Value + Mode (see below).
Fig. 10 Personality „Value"
The machine can - depending on the choosen Personality - be controlled via one or
two DMX-channels. (Adjustments via SETTINGS —> PERSONALITY).
– If Personality VALUE is choosen, the Cobra 3.1 can only be controlled via one DMX-
channel. This controls the pump value (= fog output).
– If Personality VALUE+MODE has been choosen, the machine can be controlled via
two following DMX-channels. The first channel regulates the pump, the second one
selects the pump mode. —> See chapter 5.4.1.
The second channel is divided into four ranges:
Mode
Impulse
Extended
Flood
Continuous
DMX-Value
195 - 255
130 - 194
65 - 129
0 - 64
Fig. 11 Personality „Value + Mode"