5. Operating the Cobra 3.1
Fig. 3 Main screen
After starting the Cobra 3.1, the display shows the main screen (Fig. 3). It shows the
following panels:
First line from left to right:
– Button ANALOG: shows the adjusted mode and the voltage. —> See chapter 5.4.3
– Button DMX: shows whether DMX is active and the adjusted DMX-address.
—> See chapter 5.4.4
– Button ETH: shows the selected Ethernet protocol and whether the machine is con-
trolled via Ethernet. —> See chapter 5.4.5
Second line shows
– whether the machine has reached the operating temperature or how far the heating
process has progressed. The display increases from 0 to 100%.
– which performance curve/-characteristic (= MODE) has been selected. By pressing
MODE, the display changes into the MODE-display. Here you can choose between
four different performance curves. —> See chapter 5.4.1
Third line: Actual value of fog/output (pump). The value can be changed from 0% to
100% by pressing the Plus- or Minus button. Pressing the button in the middle (FOG),
a keyboard appears where the new value can be typed in.
Fourth line:
– SETTINGS: changes into the adjusting menu.
– START: During the heating up phase the start button is red. As soon as the fogging
process can be started, the button turns green.
11