12.
Troubleshooting
PROBLEM
Oven window
or combustion
chamber's window
blackening.
Irregular draw.
Black smoke
leaking out of the
cookstove.
Smoke coming out
of the cookstove.
Page 30
POSSIBLE CAUSES
• Draft too low
• Bad air intake adjustment
• Too much combustible in the
cookstove.
• Wood with a high rate of
relative humidity > 20-25%
• Unregulated combustion.
• Inadequate or dirty chimney.
• Dirt
in
the
combustion
chamber or in the cookstove.
• Strong winds
• Ignition with green wood.
• Smoke pipe obstructed.
• Combustion chamber's door
open while the cookstove is
heating.
• Insufficient draw
• Bad adjustments of the air
inlets during startup.
• The
cookstove
must
cleaned.
SOLUTION
• Check that all the pipes are clean.
• Modify the chimney: increase the height
or check surrondings.
• Reduce the quantity of combustible in
the combustion chamber.
• Dry the wood longer.
• Sweep the chimney or have it clean by a
professional.
• Clean the cookstove.
• Relocate chimney or fresh air intake.
• Ignite
the
combustible.
• Ask for professional qualified assistance.
• Check the door closing and the tightness
of the gaskets.
• Check the chimney system.
• Eliminate or reduce to minimum the
deviations and horizontal lengths in the
chimney.
• Check all the chimney sections as well as
its height on the outside.
be
• Ask for a chimney inspection by a certified
technician.
• Regularly
clean
indicated.
Installation and operation manual - Atlas woodburning cookstove
cookstove
with
suitable
the
cookstove
as