• The installation must be able to expand: the installation of elbows allow expansion; straight
installations must have a coupling pipe with an extremity without attachment or with a telescopic
section.
• Minimum upward slope toward the chimney: 20 mm/m (¼" per foot)
• One of the installation extremities must be firmly fixed to the cookstove nozzle with three metal
screws and the other extremity firmly fixed to the chimney.
• It must be possible to clean the pipes either by a manhole or by removing the pipes. The removal
of the pipes must not require moving the cookstove.
• The male parts of the pipe sections must be toward the appliance so the ashes and the condensation
stay inside the pipe.
• A chimney connector shall not pass through an attic or roof space, closet or similar concealed
space, or a floor, or ceilling. Where passage through a waII, or partition of combustible construction
is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning
Appliances and Equipment
• The chimney connector must be in good condition and kept clean.