Checking Oil Level; Serviceair Cleaner; Engine - Craftsman 580.75151 Owner's Manual

5 horsepower 1800 psi 2.5 gpm high pressure washer
Table of Contents

Advertisement

CUSTOMER
RESPONSIBILITY
PUMP MAINTENANCE
Pump OI1: Change pump oil after first 50 hours of opera-
tion, then every 500 hours thereafter° To change pump oil,
follows these steps:
=
Place a proper container beneath the pump. You will
only need a small one because capacity
is only 5
ounces,
=
Remove the Oil Drain Plug on bottom of pump and
drain oil into the container (Fig_ 22)°
OIL DRAIN PLUG
FIG. 22
When oil has drained completely,
reinstall oil drain
plugo
o
Remove
pump's oil fill plug, insert funnel and add
recommendedSAE
20W-40 oil until level reaches full
mark on gauge located on side of the pump_
o
Reinstall the pump's oil fill plug.
ENGINE
MAINTENANCE
CHECKING OIL LEVEL
See "PREPARATION
BEFORE USE" for information on
checking oil level
Oil level should be checked prior to each
use or at least every 5 hours of operation.
Keep oil level
maintained.
CHANGING OIL
o
l
I
Change oil after first 5 hours of operation. Change oil
every 25 hours thereafter.
If you are using your pres-
sure washer under extremely dirty or dusty conditions,
or in extremely hot weather, change oil more often.
Change oil while engine is still warm from running, as
follows:
,_
CAUTION:
DISCONNECT SPARK PLUG WIRE
FROM SPARK PLUG AND KEEP IT AWAY FROM
SPARK PLUG.
o
o
o
Clean area around oildrain plug, remove plug and drain
oil completely into a suitable container (Fig. 23).
When all oil has drained, install and tighten oil plug.
Clean area around oil fill plug and remove oil fil! plug.
Fill engine crankcase with recommended
oil until oil
level is at
point of overflowing° About 20 ounces is
required° POUR SLOWLY.
FIG.
=
When engine crankcase is filled to proper level, install
and tighten oil fill plug.
SERVICE AIR CLEANER
Your engine will not run properly and may be damaged if
you run it using a dirty air cleaner°
Clean or replace the air cleaner paper filter once every 100
hours of operation or once a year, whichever comes first.
Clean or replace more often if operating under dusty or dirty
conditions. Replacements are available at your local Sears
Authorized Service Center_
To clean or replace air cleaner (Fig. 24), follow these steps:
---\
AIR CLEANER
FIG.
=
Loosen cover screws (these need not be removed) and
remove cover.
Thoroughly clean inside of base and
cover.
=
Service cartridge by tapping gently on a flat surface,
Replace if dirty. Do not oil cartridge.
°
insert cartridge (new or used) and reassemble cover to
base as it was removed before. Tighten cover screws
securely.
15