Gallagher MB1000i Instructions Manual page 19

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Gallagher 3E4345 MB1000i MB1800i MB2800i Energizer User Manual
Fence Zone 1 - 6
View the Fence Zone performances by pressing the naviga on bu ons (< or >) un l
the zone indica on arrow is highligh ng the desired fence zone (1 - 6). The fence
zones voltage, current and alarm informa on is displayed in the same way as the
Energizer output informa on. See Energizer Output and Alarms sec on (p.14).
To adjust or turn off the fence zone alarms, see Adjus ng/Turning Off Alarms sec on
(p.15).
Low Ba ery
When viewing a zone, if the ba ery icon is displayed, then the zone device needs a
ba ery replacement.
Adjus ng the energizer output voltage
a)
Press the setup bu on (
bu ons ( < or >) to highlight the quickscan bargraph display (it will start
fl ashing).
b)
Press (+ or -) to adjust the output voltage up or down. The output voltage can
be adjusted from 4.5KV to 8KV. The factory default se ng is 8KV.
c)
To exit the setup mode wait 10 seconds or press the setup bu on (
Controller showing zone 2 with a low ba ery
) to enter setup mode and use the naviga on
Controller showing the output voltage being adjusted
).
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mb2800iMb1800i

Table of Contents