SPECIFICATIONS

Built-in battery
12-volt rechargeable, lead-acid, AGM (Absorbed Glass Mat) battery
1.
2 USB power
5 volts/2400 mA maximum
2.
ports
Worklight
Five non-replaceable LEDs
3.
Charging time
AC charging – initial charge time 24 hours;
4.
typical charge time 14 to 18 hours

OPERATION

Checking Jump-Starter Battery Status

Legend
1.
Battery Status 0-5%
2.
Battery Status 25%
3.
Battery Status 50%
4.
Battery Status 75%
5.
Battery Status 100%
Press the battery status test button once and release it. The number of green LED lights that light up
will determine the battery's charge status. When all 5 LEDs are lit, the battery is fully charged. If only 1
LED lights up, the battery should be charged immediately.

Alarm - LCA Low Charge Alert

®
The Alarm - LCA Low Charge Alert
system alerts the user with an audible alarm sound that the
®
battery charge level for the Jump-Starter is getting low and it should be charged. Anytime the battery
Test/Alarm button is pressed and held for 3-4 seconds, the Alarm - LCA Low Charge Alert
can be activated or deactivated.
To activate the Alarm - LCA Low Charge Alert
®
3-4 seconds. The battery status will be displayed and the Alarm - LCA Low Charge Alert
indicator will light. The Alarm - LCA Low Charge Alert
to 5-0% (1 green LED lit), the Alarm - LCA Low Charge Alert
With the Alarm - LCA Low Charge Alert
®
feature activated, when the battery reaches a 0-5% capacity
the alarm beeps like a smoke detector with a slower pace, when the capacity of the battery reaches to
critical low (11V) the alarm beeps at a consistent fast pace to let the user know the battery is about to
be completely discharged.
The alarm can be put into a "snooze" mode for a period of 24 hours. To put the alarm into a snooze
mode for 24 hours, short press the Test/Alarm button. The Alarm - LCA Low Charge Alert
LED indicator light will turn off, and the alarm will be silenced for 24 hours. If the Jump-Starter is not
charged, the alarm will be activated again in 24 hours. To prevent the alarm from sounding again, fully
charge the battery.
To disable the Alarm - LCA Low Charge Alert
®
seconds. The Blue LED light will turn OFF and the feature will be disabled.
1
2
3
4
5
®
feature
system, press and hold the Test/Alarm button for
®
blue LED
®
is now activated. If the battery charge status falls
®
will sound.
®
blue
feature press and hold the Test/Alarm button for 3-4
6