Initial Installation Procedure

4.3 Installation

Before the unit can be installed it is necessary to have the comments / approvement
of the responsible gas supply company.
Only a installation company which is approved by the responsible gas supply compa-
ny is allowed to set up the unit, install the gas connection and to start the operation.
The laws, technical regulations and directions mentioned under section 4.2.3 have to
be observed. Only approved companies are allowed to do maintenance work or gas
adjustments and they have to observe this manual and corresponding regulations.
4.3.1 Statutory orders, technical regulations and directives
The following regulations have to be observed when the unit is set up:
• local statutory orders
• local laws valid for your countries
• technical regulations for fluid gas
• directions of the local gas supply company
Furthermore regulations of accident prevention valid for your country have to be ob-
served.
For operating the unit outside Germany the national laws, technical regulations and
directions of the specific country are valid.
4.3.2 Gas connection
Check whether the gas unit is adjusted for the existing kind of gas. Compare the indi-
cated kind of gas on the type plate with the existing kind of gas. If this is not the case
an adjustment according to the local requirements is necessary. The gas connection
depends on the rotisserie model (external thread right acc. to DIN-ISO 7/1 [DIN 2999,
part 1] 1 inch). The connection with the gas supply has to be made through the inter-
mediary of a connection armature and through a thermically secured shutoff device.
Technical regulations have to be observed. Only an approved technician is allowed to
do this work. After the gas connection has been made all points of connection have to
be tested for leaks under operation pressure by leak detecting spray or by brushing
with foam forming mediums which do not cause corrosion.
4.3.3 Electrical connection
Note! Note that also after installation and electrical connection the plug must be ac-
cessible. If this is not possible due to structural reasons, or if the unit is connected
permanently, the power supply needs to have an interlock switch.
Note! During any servicing, take care that the unit is disconnected from the mains!
Not paying attention may result in injury!
Please learn the electrical and technical data of your unit from the nameplate.
·
The unit is ready for plug-in.
·
For power supply a shockproof socket is necessary.
·
Make sure the supply cable is protected separatly with 16 Amps.
The existing connection cable for the electrical connection is positioned at the lower
printed: 03/2012 Subject to change!
15