Basic Function:
Used to drain water from the tub
•
Used to release brake
•
Circuit:
Electrical Parameter:
Motor type
Nominal power
Nominal voltage
Nominal Current
Nominal resistor (25°C)
Inductance
Connector Type:
Number of circuits
Brake Actuator
Control unit
Test:
Check the resistance of the brake actuator as per the above value
BRAKE ACTUATOR
BRAKE ACTUATOR
:
Permanent Magnet Synchronous type
:
< 4W
:
230V
:
<0.03A
:
7.5 – 8.5 kΩ
:
7.87 H
:
2
:
4.8 x 0.5 Tab Housing
:
Mini-fit Jr 6-ckt Board-in connector (Load Connector - LC)