This routine is helpful to test the Spin Function in the production line.
To invoke this routine, bring the control to PROGRAMMING State from OFF State by pressing On/Off key.
1) Keep pressing the Wash Option key, press the Special Cycle key twice with interval between two key presses above 100 ms.
2)Provide a delay of 10 secs. The control goes for direct spin for 4 mins.
3)Spin LED to be continuously on and all other LEDs to be turned off.
4)Seven Segments should be turned off.
5)Once the cycle is completed, EOC beep to be generated.
6)The control should go to OFF state after EOC.
During Spin routine, lid switch has to be satisfied (Lid has to be closed). Pressure sensor input has to be in the reset level.
This routine cannot be activated during RUNNING / PAUSE State. It can be activated only during PROGRAMMING State.
SPIN TEST ROUTINE
SPIN TEST ROUTINE