Installation Vitodens 242-F - Viessmann VITODENS 242-F Technical Manual

Gas condensing storage combi boiler 1.9 to 35.0 kw for natural gas and lpg gas condensing storage combi boiler 1.9 to 26.0 kw for natural gas and lpg gas/solar condensing storage combi boiler with solar dhw heating 1.9 to 26.0 kw for natural gas and lpg
Table of Contents

Advertisement

Design information

Installation Vitodens 242-F

Connection sets for installation on finished walls, for upward
connection
Connection set without pre-mounting bracket, part no. 7348552
440
330
220
55
A
B
C
D
E F
G
5
A
B
C
D
E F
G
A Solar return R ¾/Ø 22 mm
B Heating flow R ¾
C DHW R ½
D DHW circulation R ½ (separate accessory)
Type
Vitodens 242-F, B2UB
Note
The adjustable feet give the height measurements of the connec-
tions a tolerance of + 7 mm.
For connecting the on-site gas, heating water and DHW lines from
above.
VIESMANN
56
(cont.)
H
H
a
mm
1927
Connection set with pre-mounting bracket for pre-installation in
unfinished buildings, part no. 7351778
440
330
220
55
A
B
C
D
E F
A
B
C
E F
D
E Gas connection R ½
F Cold water R ½
G Heating return R ¾
H Solar flow R ¾/Ø 22 mm
b
c
mm
mm
mm
1964
1976
1890
Connection set comprising:
■ Fitting assembly (only for part no. 7351778)
■ Connection pipes
■ Shut-off valves for heating water flow and return, with boiler drain
& fill valve
■ 2 connectors for DHW
■ 2 connectors each for solar flow and return (R ¾/Ø 22 mm)
■ Gas shut-off valve with thermally activated safety shut-off valve
G
H
G
H
d
e
f
mm
mm
1940
2011
g
mm
2023
VITODENS

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2ubB2sbB2tb

Table of Contents