LEDRU LED 0-10V Zone Controller Installation Guide
Package Contents
LED Relay Zone
Controller
Product Description
The LED relay zone controller uses wireless technology to
communicate with other self-powered EnOcean based
products and provides an amazingly simple solution for
dimming control of LED lighting.
The compact size enables flexible installation inside of or
next to electrical boxes and fixtures so it can be easily wired
out of sight using standard wiring practices.
Simply link the module to an EnOcean-based motion sensor,
light level sensor or rocker switch and experience levels of
efficiency and convenience that can only be achieved
through wireless controls.
It is also possible to connect a 12V DC powered, wired
occupancy sensor.
Product Features Include:
Enables wireless dimming of a single fixture or a zone of
multiple daisy chained LED fixtures (e.g. 20 each 30W or
10 each 60W).
Supports California Title 24 daylight harvesting scenarios,
occupancy control and manual dimming with input from
self-powered wireless switches and sensors. Implements
load shedding initiated by separate Demand Response
controllers
Installs inside or mounts to electrical box using threaded
connector
Supports wireless remote commissioning to link devices
and set parameters
© 2018 EnOcean GmbH V3.0
Tools Required
Screwdriver
Wire nuts
LEDRU-W-EO / LEDRU-W-AU DD08 and up
Specifications (typ. values)
Power Supply
120V - 277V VAC, 60 Hz
Maximum Load
General Purpose: 16A @ 120/277VAC
Resistive: 16A @ 120/277VAC
Tungsten: 960W @ 120VAC
Ballast / LED Driver: 600W @ 120VAC
0-10V output
Tolerances +3%/-4% (1-10V range)
Current sinking 35mA*, sourcing 20mA
Power Consumption 1W full load
0.35W quiescent
Surge Protection
3kV line to line, exceeding
IEC61000-4-5 installation class 4
Inputs/Outputs
Flying-lead style wires:
Local User Interface
2 Buttons, 1 bi color LED for device
configuration & manual control
RF Standard
EnOcean 902 MHz (LEDRU)
Transmission Range
100 ft. (30 m)
Status reporting EEP
D2-40-00 (default)
(Outbound EnOcean
A5-11-01 (alternate)
Equipment Profile)
A5-38-08 (Master / Gateway)
RECOM
V1.1 - Compatible with Navigan™
Interoperable
Rocker Pad Switch (F6-02-02)
Products / EEPs
Occupancy Sensor
(Inbound EnOcean
(A5-07-01, A5-07-02, A5-07-03)
Equipment Profiles)
Light Level Sensor
(A5-06-02, A6-06-03)
Central Controller (A5-38-08)
Demand Response (A5-37-01)
Dimensions
2.78" H x 1.65" W x 1.1" D
(73mm x 42mm x 28mm)
Weight
3.2oz. (90g)
Mounting
Environment
Agency Compliance
UL244A, UL 1472, CSA/CAN
C22.2 No. 184.1, FCC, IC
UL2043 Plenum Rated
2 power input wires
1 switched output wire
0-10V control output
12V DC external occupancy sensor
Interface (25mA load max)
only for
LEDRU-W-AU
Connect to electrical boxes and
fixtures using threaded nipple
Install inside standard electrical box
Indoor use only
32° to 140° F (0° to 60° C)
20% to 85% relative
humidity (non-condensing)
Page
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEDRU and is the answer not in the manual?

Questions and answers

Summary of Contents for EnOcean LEDRU

  • Page 1 RECOM V1.1 - Compatible with Navigan™ Interoperable Rocker Pad Switch (F6-02-02) Simply link the module to an EnOcean-based motion sensor, Products / EEPs Occupancy Sensor light level sensor or rocker switch and experience levels of (Inbound EnOcean...
  • Page 2 NOTE: Use a non-metal electrical enclosure for best shown in figure A. wireless communication performance. 7. LEDRU-W-AU models only: If connecting an external Identify the wiring connection at the installation site to Occupancy sensor, use the orange 12V DC out wire to coordinate with the following wiring diagram.
  • Page 3: Device Configuration

    LEDRU LED 0-10V Zone Controller Installation Guide 4. Linking only or capped. DO NOT WIRE HOT!! Linking is the process by which different devices are configured to work with each other in a system. Sometimes this process is also called “Teach-in” or “Learn-in”.
  • Page 4: Operating Modes

    LEDRU LED 0-10V Zone Controller Installation Guide 3. For a linked transmitter to be unlinked, just send another link message using the same action as described in 1. If Setting the minimum output voltage level the device has been unlinked successfully, the LRN LED...
  • Page 5: Functional Behavior

    LEDRU LED 0-10V Zone Controller Installation Guide Light can be switched OFF automatically in absence of a controller timeout the system will switch back to the previous state. linked occupancy sensor if no user (switch) action occurs during a period defined by RockerSwitchAutoOffTimer.
  • Page 6: Troubleshooting

    LEDRU LED 0-10V Zone Controller Installation Guide If the user has switched the light OFF (by a linked switch) The LED controller provides the option to activate one-level then it can be turned ON again by occupancy sensor input (repeat only original telegrams) or two-level (repeat original only after OccAutoOnDelay (default 15 minutes).
  • Page 7 LEDRU LED 0-10V Zone Controller Installation Guide harmful interference, and (2) this device must accept any interference received, level if AutoOffTimer1 elapses Range: 0-200% including interference that may cause undesired operation. OccAutoOffLevel2 Output value to which lights will IMPORTANT! Any changes or modifications not expressly approved by the party be dimmed if AutoOFFtimer2 responsible for compliance could void the user’s authority to operate this...
  • Page 8 LEDRU LED 0-10V Zone Controller Installation Guide Default / Link Health Mode Can be used to check RSSI levels of disabled Description Parameter inbound links, LED controller will Notes send a special message for every System Parameters link based event or the entire...

Table of Contents