Westfield MKX100 SERIES Assembly Manual

Westfield MKX100 SERIES Assembly Manual

Grain augers

Advertisement

MKX100-SERIES GRAIN AUGERS
MKX100-53/63/73/83
ASSEMBLY MANUAL
ORIGINAL INSTRUCTIONS
Read this manual before using product. Failure
Part Number: 30908 R3
to follow instructions and safety precautions can
Revised: 15/1/18
result in serious injury, death, or property
damage. Keep manual for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MKX100 SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Westfield MKX100 SERIES

  • Page 1 MKX100-SERIES GRAIN AUGERS MKX100-53/63/73/83 ASSEMBLY MANUAL ORIGINAL INSTRUCTIONS Read this manual before using product. Failure Part Number: 30908 R3 to follow instructions and safety precautions can Revised: 15/1/18 result in serious injury, death, or property damage. Keep manual for future reference.
  • Page 3: Table Of Contents

    - MKX100-S ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 TABLE OF CONTENTS 1. Introduction .......................... 5 2. Safety ............................ 7 2.1. General Safety Information ..................7 2.2. Assembly Safety....................... 8 2.3. PTO Safety....................... 9 2.4. Hydraulic Safety ....................... 9 2.5. Safety Decals ......................9 2.5.1.
  • Page 4 - MKX100-S ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 30908 R3...
  • Page 5: Introduction

    UGERS NTRODUCTION MKX100-53/63/73/83 1. Introduction This manual describes how to assemble the Westfield MKX100-Series Grain Augers. Before assembling this equipment, please read this manual. Familiarize yourself with the process and the necessary precautions for efficient and safe assembly. Anyone present at the assembly site is required to be familiar with all safety precautions.
  • Page 6 1. I - MKX100-S NTRODUCTION ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 30908 R3...
  • Page 7: Safety

    - MKX100-S 2. S ESTFIELD ERIES RAIN UGERS AFETY MKX100-53/63/73/83 2. Safety 2.1. GENERAL SAFETY INFORMATION The Safety Alert symbol identifies important safety messages on the product and in the manual. When you see this symbol, be alert to the possibility of personal injury or death.
  • Page 8: Assembly Safety

    2. S - MKX100-S AFETY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 YOU are responsible for the SAFE use and maintenance of your equipment. YOU must ensure that you and anyone else who is going to work around the equipment understands all procedures and related SAFETY information contained in this manual.
  • Page 9: Pto Safety

    - MKX100-S 2. S ESTFIELD ERIES RAIN UGERS AFETY MKX100-53/63/73/83 2.3. PTO SAFETY • Never use a PTO driveline without a rotating shield in good working order. • Ensure PTO driveline is securely attached at both ends before operating. • Before starting tractor, turn power to PTO to the off position (where applica- ble).
  • Page 10: Safety Decal Locations And Details

    Please review the decals shown. If your auger does not have these decals, they are available upon request. Please specify which decals you need. * Westfield reserves the right to update safety decals without notice. Safety decals may not be exactly as shown.
  • Page 11 - MKX100-S 2. S ESTFIELD ERIES RAIN UGERS AFETY MKX100-53/63/73/83 DECAL #20806 WARNING HIGH PRESSURE FLUID HAZARD Hydraulic fluid can cause serious injury if it penetrates the skin. If it does, see a doctor immediately. • Relieve pressure before unhooking hydraulic line. •...
  • Page 12 2. S - MKX100-S AFETY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 DECAL #17531 NOTICE To prevent damage during auger-to- tractor hookup: • Follow dimensions above for correct auger-to-tractor hookup. • Auger must be on level ground and in full down position when measuring. •...
  • Page 13 - MKX100-S 2. S ESTFIELD ERIES RAIN UGERS AFETY MKX100-53/63/73/83 DECAL # 17378 DECAL #20811 DECAL #20813 WARNING NOTICE DANGER This equipment is not intended for transport on public roads. If it must be moved, check local regulations. To avoid damaging the equipment: UPENDING HAZARD ROTATING FLIGHTING HAZARD •...
  • Page 14 2. S - MKX100-S AFETY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 WARNING WARNING DECAL #20816 TRANSPORT HAZARD DANGER To prevent serious injury or death: To prevent serious injury or death: • Securely attach equipment to vehicle with correct pin and safety chains. •...
  • Page 15 - MKX100-S 2. S ESTFIELD ERIES RAIN UGERS AFETY MKX100-53/63/73/83 DECAL #20812 WARNING ROLLOVER / TRANSPORT HAZARD To prevent serious injury or death: • Fully extend axles before raising auger tube. 20812 Made in • Retract axles before transporting. Canada NOTE: THIS WARNING DECAL IS ONLY INCLUDED ON AUGERS 83’...
  • Page 16 2. S - MKX100-S AFETY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 30908 R3...
  • Page 17: Assembly

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3. Assembly WARNING Before continuing, ensure you have read and understand the relevant information in the safety section. Safety information is provided to help prevent serious injury, death, or property damage. Before beginning assembly, familiarize yourself with all the sub-assemblies and hardware making up the auger.
  • Page 18 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 • Grease • Impact wrench and sockets • 2+ Steel Punches (for aligning bolt holes) See Table 3.1. for a list of assembly procedures. Table 3.1. Assembly Procedures Procedure Page Identify and Arrange Auger Tube Sections page 19 Install Hydraulic Lift Cylinders...
  • Page 19: Assemble The Auger Tube

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.2. ASSEMBLE THE AUGER TUBE 3.2.1. I DENTIFY AND RRANGE UGER ECTIONS 1. Align tube sections on a series of support stands, placing a support stand at the end of each tube (see the figures below for correct tube identification and positioning).
  • Page 20 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 21709 21704 21700 Figure 3.3 MKX100-73 Auger Tube Sections 21710 21713 21712 21706 Figure 3.4 MKX100-83 Auger Tube Sections 30908 R3...
  • Page 21: Install Hydraulic Lift Cylinders

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.2.2. I NSTALL YDRAULIC YLINDERS 1. Identify the tube section where the hydraulic lift cylinders install, and rotate the section so that the cylinder mount brackets are facing up.  2.
  • Page 22 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 7/16” LOCKNUTS [19598] CYLINDER RAM GUIDE [27486] 5/16” X 2-1/2” ROLL PIN [28584] 7/16” X 1” BOLTS [19542] Figure 3.6 Installing Lift Cylinder (MKX100-83) 30908 R3...
  • Page 23: Connect Auger Tube Sections Together

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.2.3. C ONNECT UGER ECTIONS OGETHER Important: Always strap tubes to the support stands to prevent the tubes from rolling off the stands. Note: Assemble the auger tube starting with the discharge section and working toward the intake section.
  • Page 24: Install The Track Shoe, Trackstop, & Lift-Assist Arm

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.2.4. I , & L NSTALL THE RACK RACKSTOP SSIST 1. Slide the double roller track shoe onto the track from the spout end of the tube. 2. Slide track shoe along full length of track to make certain there is no binding and that track ends are properly aligned.
  • Page 25 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 MKX100-53 MKX100-63 MKX100-73 Figure 3.9 MKX100-53/63/73 Trackstop Locations Figure 3.10 MKX100-83 Trackstop Location 30908 R3...
  • Page 26: Angle Ring Support Bracket

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.2.5. A NGLE UPPORT RACKET  MKX100-83 M ODEL Once the tubes are bolted together, install the angle ring support brackets at each connecting location between the tubes. 1. At the connection location between each of the tubes, install an angle ring support bracket by inserting one end at a time through the existing holes in the tabs located in the track.
  • Page 27: Install The Boot On The Auger Tube

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.2.6. I NSTALL THE OOT ON THE UGER TUBE WARNING Components are heavy and create a crushing hazard if improperly handled. Be sure to use proper hoisting equipment and procedures, and ensure lifting apparatus is secure.
  • Page 28 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 TUBE FLANGE NOTE: ALL BOLTS ARE 7/16” X 1” BOLTS [19542] AND ALL NUTS ARE 7/16” LOCKNUTS [19598] Figure 3.13 Install Boot on Auger Tube 3. Install the Lower Sprocket as follows: a.
  • Page 29 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 1-1/2” RIM WASHER 5/8” X 1-3/4” BOLTS [21707] 5/8” LOCKNUTS [18544] [19600] LOWER DRIVE BEARING CHAIN LOWER LOCK COLLAR SPROCKET SQUARE KEY [21567] [21758] Figure 3.14 Installing Boot Bearing, Sprocket, and Chain Note: It is recommended you use a thread locking compound that meets or exceeds Loctite Blue©...
  • Page 30: Install The Discharge Spout

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.2.7. I NSTALL THE ISCHARGE POUT ISCHARGE POUT 1. Align the discharge spout over the opening in the upper tube. 2. Attach the discharge spout with two 7/16” x 1-1/4” GR8 bolts [18698] and  7/16”...
  • Page 31: Set The Thrust Adjuster

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.2.8. S ET THE HRUST DJUSTER 1. Remove the upper bearing lock collar (if necessary). 2. Slide the lock collar and bushing onto the shaft and attach the 1-1/4” nut. 3.
  • Page 32: Apply Logo And Model Decals On The Auger Tubes

    ODEL ECALS ON THE UGER UBES Note: See the model-specific figures on the following page for Westfield logo and model decal locations. 1. Prepare surface by cleaning thoroughly with soap and water. Surface must be clean and free of dirt, grime, rust and oil.
  • Page 33 ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 MODEL DECAL 21699 21700 WESTFIELD LOGO DECAL Figure 3.16 MKX100-53 Logo and Model Decal Locations 21702 MODEL DECAL 21704 21700 WESTFIELD LOGO DECAL Figure 3.17 MKX100-63 Logo and Model Decal Locations 21709 MODEL DECAL...
  • Page 34 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 21710 MODEL DECAL 21713 21712 21706 WESTFIELD LOGO DECAL Figure 3.19 MKX100-83 Logo and Model Decal Locations 30908 R3...
  • Page 35: Install Truss Support Brackets And Truss Cables

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.3. INSTALL TRUSS SUPPORT BRACKETS AND TRUSS CABLES 1. Fasten lower truss anchor to bracket. • use two 7/16” x 1” bolts and locknuts on the bracket welded to the lower tube 2.
  • Page 36 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 1: STANDARD TRUSS BRACKET [19324] 2: 7/16” X 1” BOLTS [19542] 3: 7/16” NUTS [19598] Figure 3.20 MKX100-53 Truss Supports 1: STANDARD TRUSS BRACKET [19324] 2: 7/16” X 1” BOLTS [19542] 3: 7/16”...
  • Page 37 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 1: STANDARD TRUSS BRACKET [19324] 2: HIGH TRUSS [19325] 3: 7/16” X 1” BOLTS [19542] 4: 7/16” NUTS [19598] Figure 3.22 MKX100-73 Truss Supports 1: STANDARD TRUSS BRACKET [19324] 2: HIGH TRUSS [19325] 3: 7/16”...
  • Page 38 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 1: 7/16” X 1” BOLT [19542] 2: 7/16” LOCKNUT [19598] 3: TRUSS CABLE BRACKET [18032] 4: CABLE CLAMP (5/16” FOR MKX100-53/63/73 [19333], 3/8” FOR MKX100-83 [18990]) 5: 1/2” EYEBOLT[19331] 6: TOP CABLE 7: BOTTOM CABLE NOTE: THE CONFIGURATION SHOWN HERE (TRUSSING ABOVE AND BENEATH THE TUBE) APPLIES ONLY TO MKX100-73/83, BUT ALL OTHER DETAILS ARE THE SAME ACROSS ALL MODELS.
  • Page 39: Assemble The Frame (Mkx100-53/63/73 Models)

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.4. ASSEMBLE THE FRAME (MKX100-53/63/73 MODELS) 1. Fasten the lower reach arms to the axle with three 1/2” x 1-1/4" bolts and locknuts on each side. 2. Attach the long cross member to the bottom of large on the lower reach arms with two 1/2”...
  • Page 40 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 Table 3.2 MKX100-53/63/73 Lower Frame Parts Number Description MKX100‐53 MKX100‐63 MKX100‐73 Lower Reach Arm, RH 19790 19358 19360 Lower Reach Arm, LH 19789 19359 19361 Axle 18090 19342 19343 Frame Cross Brace 19796 19796 19796...
  • Page 41: Assemble The Frame (Mkx100-83 Model)

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.5. ASSEMBLE THE FRAME (MKX100-83 MODEL) 1. Fasten the lower reach arms to the axle with three 5/8” x 2" bolts and locknuts on each side. 2. Attach the two corner braces between the lower frame assembly and the axle with two 1/2”...
  • Page 42 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 Table 3.3 MKX100-83 Lower Frame Number Description MKX100‐83 Lower Reach Arm, LH 27492 Lower Reach Arm, RH 27491 Axle 27489 Frame Cross Brace 27500 Frame Stabilizer Brace 27504 Short Cross Member 27493 1/2"...
  • Page 43: Assemble The Wheel Hub And Install Tires

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.6. ASSEMBLE THE WHEEL HUB AND INSTALL TIRES 1. Remove any dirt or paint from spindle and hub. 2. Thoroughly pack wheel bearings and cups with a good grade of bearing grease.
  • Page 44: Connect The Auger Tube To The Frame

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.7. CONNECT THE AUGER TUBE TO THE FRAME 1. Raise the discharge end of auger with a front end loader and a strong sling/ chain or block and tackle. The height should be sufficient to clear the undercarriage assembly.
  • Page 45 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 Figure 3.28 Connecting the Auger Tube to Frame (MKX100-53/63/73) Table 3.4. MKX100-53/63/73 Upper Frame Parts Number Description MKX100-53 MKX100-63 MKX100-73 Stabilizer Bracket 18909 18909 18909 3/4" x 2" Bolt 19592 19592 19592 3/4"...
  • Page 46 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 Figure 3.29 Connecting the Auger Tube to Frame (MKX100-83) Table 3.5. MKX100-83 Upper Frame Parts Number Description MKX100-83 Stabilizer Bracket 27494 3/4" x 2-1/4" Bolt 29254 3/4" Washer 19979 1-1/4” x 5/8” (Short) Spacer Bushing 27508 1-1/4”...
  • Page 47: Install The Auger Tube Lift Cylinders And Cables

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.8. INSTALL THE AUGER TUBE LIFT CYLINDERS AND CABLES CAUTION The lift assist arm must rest against track stop when adjusting cable. If this isn’t done, the auger can raise higher than designed to lift, resulting in damage to auger and possible injury to personnel.
  • Page 48: Connect Hydraulic Hoses And Ball Valve

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.9. CONNECT HYDRAULIC HOSES AND BALL VALVE Note: Determine right or left side of auger by standing at intake end facing top discharge end. Note: Elbow fittings are factory installed. Use thread sealant on fitting and hose threads (not supplied.) WARNING Wear on hose can cause auger to drop...
  • Page 49 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 Table 3.6 Hydraulic Cylinder and Hoses Model Cylinder Pressure Hose Return Hose MKX100-53 18033 21608 MKX100-63 18034 20318 MKX100-73 18035 20320 MKX100-83 27506 27480 20320 Figure 3.31 MKX100-53, MKX100-73 Hydraulic Hose Cylinder Connection Figure 3.32 MKX100-63 Hydraulic Hose Cylinder Connection 30908 R3...
  • Page 50 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 Figure 3.33 MKX100-83 Hydraulic Hose Cylinder Connections 1/4” X 3/4” BOLTS [9900800] AND 1/4” LOCKNUTS [28449] Figure 3.34 Installing the Ball Valve on the Boot 30908 R3...
  • Page 51: Connect The Pto Driveline

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.10. CONNECT THE PTO DRIVELINE 1. Install the PTO transport bracket using two 1/2” x 1-1/4” bolts (19588) and two 1/2” nuts (19599). 2. Clean paint or dirt off of PTO driveline and flighting shaft ends before assembly.
  • Page 52: Install Low Profile Intake Hopper

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.11. INSTALL LOW PROFILE INTAKE HOPPER WARNING Components are heavy and create a crushing hazard if improperly handled. Be sure to use proper hoisting equipment and procedures, and ensure lifting apparatus is secure. Lockout the lifting apparatus before working around or under the raised components.
  • Page 53 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 7. Attach the 4 solid wheels to the 4 hopper corners with the axle pins and hairpins. There are 3 height settings (Figure 3.38) that can be used according to preference. 8.
  • Page 54 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 INSPECTION HATCH BAR AND HAIRCLIP WHEEL, WHEEL PIN, AND HAIRCLIP Figure 3.38 Connecting the Wheels, Inspection Hatch Bar, and Hopper  Cable Attach Bracket SPOUT HEAD SERVICE COVER RIM WASHER [17370] 3/8”...
  • Page 55: Install The Hopper Lift Extension

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.12. INSTALL THE HOPPER LIFT EXTENSION  MKX100-83 only: 1. Place the hopper lift extension onto the bracket on the lower tube as shown. 2. Secure by using the 2 lift extension brackets and six 7/16” x 1-1/4” bolts and locknuts.
  • Page 56 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 8. To place hopper into transport position, attach cable hook to hook on the hopper transition, then fully raise hopper with intake side facing main auger. Secure hopper to lift arm by connecting the safety chain (Figure 3.44) to the hopper cable attach bracket.
  • Page 57 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 CABLE CLAMP WINCH CABLE Figure 3.43 Connecting Winch Cable to Spool WINCH CHAIN TRANSPORT CHAIN AND HOOK AND HOOK Figure 3.44 Transport Position, Safety Chain and Winch Hook 30908 R3...
  • Page 58: Install The Hitch Jack

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83  If you want to change the side of intake feed hopper operation: a. Raise auger hitch jack and disconnect from tractor. b. Swing intake feed hopper to opposite side of auger. c.
  • Page 59: Install The Plastic Manual Container

    - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 3.15. INSTALL THE PLASTIC MANUAL CONTAINER Mount the plastic manual holder directly to the boot (as shown below) using three #14 x 5/8” self-tapping screws (19274). Figure 3.46 Installing the Plastic Manual Container 30908 R3...
  • Page 60: Auger-To-Tractor Hookup

    3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 3.16. AUGER-TO-TRACTOR HOOKUP Important: Auger must be correctly connected to the tractor for all operations, including during transport, raising, placement, and augering grain. The final stage of the assembly is attaching the auger to the tractor. To secure the auger hitch to the tractor, use: •...
  • Page 61 - MKX100-S 3. A ESTFIELD ERIES RAIN UGERS SSEMBLY MKX100-53/63/73/83 A: 14” (35.6 CM) B: 6” - 10” (15.2 CM - 25.5 CM) C: 34-1/2” - 36-1/2” (87.6 CM - 92.7 CM) Figure 3.48 Measurements Between Drawbar and PTO Driveline MEASUREMENT PROBLEM SOLUTION...
  • Page 62 3. A - MKX100-S SSEMBLY ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 30908 R3...
  • Page 63: Appendix

    - MKX100-S 4. A ESTFIELD ERIES RAIN UGERS PPENDIX MKX100-53/63/73/83 4. Appendix 4.1. SPECIFICATIONS Important: Westfield Industries reserves the right to change specifications without notice. Table 4.1 Specification MKX100-53 MKX100-63 MKX100-73 MKX100-83 CAPACITY Unloading Rate 6600 Bu/Hr DIMENSIONS 10” 10”...
  • Page 64: Bolt Torque Values

    4. A - MKX100-S PPENDIX ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 4.2. BOLT TORQUE VALUES Tables 4.2 and 4.3 give correct torque values for various bolts and capscrews. The bolt diameter is measured to the outside of the threads. When tightening all bolts, tighten the nut on the bolt to the torque specified in the tables, unless otherwise specified.
  • Page 65: Lift Cylinder Hydraulics

    This auger is elevated with a 4” bore (the MKX100-83 has a 4-1/2” bore), and single acting hydraulic cylinder and cable. The following table lists the psi required to raise specific auger sizes (as determined by Westfield testing). These tests used a hydraulic pressure gauge (4000 psi maximum rating) and are solely intended to be used as a guide.
  • Page 66: How To Charge The Lift System

    4. A - MKX100-S PPENDIX ESTFIELD ERIES RAIN UGERS MKX100-53/63/73/83 4.4. HOW TO CHARGE THE LIFT SYSTEM  MKX100-83 Only Important: The hydraulic cylinders are shipped without oil and must be charged with oil before auger is put into operation. The cylinder will require about 9 L (2.5 US gallons).
  • Page 67: Warranty

    Company, or to our factory, with transportation charges prepaid. This warranty does not obligate Westfield Industries Ltd. to bear the cost of labor in replacing defective parts. Any defects must be reported to the Company before the end of the one year period.
  • Page 68 P.O. Box 39 Rosenort, Manitoba, CANADA R0G 1W0 Phone: (866) 467-7207 (Canada & USA) or (204) 746-2396 Fax: (866) 768-4852 Website: www.grainaugers.com Email: sales@grainaugers.com Part of the Ag Growth International group © Ag Growth International Inc. 2018 Printed in Canada...

This manual is also suitable for:

Mkx100-53Mkx100-63Mkx100-73Mkx100-83

Table of Contents