• Install a SATA host adapter that supports autonegotiation, leave the drive jumper block set to "Normal
operation" (see Figure 3, page 22 below), and connect the drive to that adapter. This option has the benefit of
not limiting the drive to a 1.5 Gbits/sec transfer rate.
3.0 Gbits per second operation
Limit data transfer rate to
1.5 Gbits per second
Jumper block
SATA power connector
SATA interface connector

Figure 3. Serial ATA connectors

4.3

Serial ATA cables and connectors

The Serial ATA interface cable consists of four conductors in two differential pairs, plus three ground connec-
tions. The cable size may be 30 to 26 AWG with a maximum length of one meter (39.37 inches). See Table 5
for connector pin definitions. Either end of the SATA signal cable can be attached to the drive or host.
For direct backplane connection, the drive connectors are inserted directly into the host receptacle. The drive
and the host receptacle incorporate features that enable the direct connection to be hot pluggable and blind
mateable.
For installations which require cables, you can connect the drive as illustrated in Figure 4, page 22.
Signal connector
Signal cable
Power cable

Figure 4. Attaching SATA cabling

Each cable is keyed to ensure correct orientation. Constellation Serial ATA drives support latching SATA con-
nectors.
4.4

Drive mounting

You can mount the drive in any orientation using four screws in the side-mounting holes or four screws in the
bottom-mounting holes. See Figure 5, page 23 for drive mounting dimensions. Follow these important mount-
ing precautions when mounting the drive:
• Allow a minimum clearance of 0.030 inches (0.76 mm) around the entire perimeter of the drive for cooling as
a guideline. Please refer to Section 4.5 for final cooling requirements.
• Use only M3 x 0.5 metric mounting screws.
• Four (4) threads (0.080 inches) minimum screw engagement recommended. Also ensure maximum screw
length does not bottom out in mounting holes.
• Do not overtighten the mounting screws (maximum torque: 4.5 inch-lb, ± 0.45 in-lb).