Wacker Neuson LB 1 Operator's Manual
Wacker Neuson LB 1 Operator's Manual

Wacker Neuson LB 1 Operator's Manual

Indirect lighting system

Advertisement

Quick Links

OPERATOR'S MANUAL
0
1
6
3
7
2
1
E
N
0163721en
0708
Indirect Lighting
System
LB 1
003

Advertisement

Table of Contents
loading

Summary of Contents for Wacker Neuson LB 1

  • Page 1 0163721en 0708 Indirect Lighting System LB 1 OPERATOR’S MANUAL...
  • Page 3: Table Of Contents

    LB 1 Table of Contents Foreword Safety Information Callouts Found in this Manual .............. 5 Safety Guidelines for Operating the Machine ........6 Guidelines for Service Safety ............... 7 Labels ....................8 Operation Intended Use ..................9 Setting up the Balloon ................ 10 Setting up the Tripod ................
  • Page 4 Refer to the separate Repair Manual for detailed instructions on servicing and repairing the machine. If you are missing any of these documents, please contact Wacker Neuson Cor- poration to order a replacement or visit www.wackerneuson.com. When ordering parts or requesting service information, be prepared to provide the machine model number, item number, revision number, and serial number.
  • Page 5: Safety Information

    LB 1 Safety Information Safety Information Callouts Found in this Manual This is the safety alert symbol. It is used to alert you to potential personal hazards. Obey all safety messages that follow this symbol. DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 6: Safety Guidelines For Operating The Machine

    Familiarize yourself with the location and proper use of all controls and safety devices. Contact Wacker Neuson Corporation for additional training if necessary. When operating this machine: Do not allow improperly trained people to operate the machine. People operating the machine must be familiar with the potential risks and hazards associated with it.
  • Page 7: Guidelines For Service Safety

    Do not defeat safety devices. Do not modify the machine without the express written approval of the manufacturer. Replacing When maintaining this machine: parts and Use only spare parts recommended by Wacker Neuson Corporation. labels Replace all missing and hard-to-read labels. wc_si000219gb.fm...
  • Page 8: Labels

    Safety Information LB 1 Labels wc_si000219gb.fm...
  • Page 9: Operation

    Operation Intended Use Intended use The LB 1 is intended to illuminate work areas. The end user assumes all responsi- bility for operating the machine safely and within its specified parameters. Local Consult with local authorities to determine regulations limiting noise and light emis- regulations sions in the work area.
  • Page 10: Setting Up The Balloon

    Operation LB 1 Setting up the Balloon Prerequisites Balloon Light fixture with bulb Procedure Follow the procedure below to set up the balloon. 1. Remove the light from the transport cylinder. 2. Remove the light from the transport bag. WARNING Electric shock hazard.
  • Page 11: Setting Up The Tripod

    LB 1 Operation Setting up the Tripod Prerequisites Tripod Procedure Follow the procedure below to set up the tripod. WARNING Electric shock hazard. Electric shock can cause serious injury or death. Never connect the light to its power source and never turn it on until it has been fully unpacked and assembled to the tripod! 1.
  • Page 12: Assembling The Balloon To The Tripod

    Operation LB 1 Assembling the Balloon to the Tripod Prerequisites Tripod Procedure Follow the procedure below to assemble the balloon to the tripod. WARNING Electric shock hazard. Electric shock can cause serious injury or death. Never connect the light to its power source and never turn it on until it has been fully unpacked and assembled to the tripod! 1.
  • Page 13 12 –15 feet). Loosen the mast clamps on the tripod and adjust the height of each section as desired. Tighten all mast clamps securely. 5. Three metal stakes (d) are provided with the LB 1. Pound each into a suitable ground location and loop the free ends of the support ropes around them to anchor the machine.
  • Page 14: Turning On/Off The Light

    Turning ON/OFF the Light Prerequisites Ballast and power source LB 1 assembled Turning on Follow the procedure below to turn on the light. 1. Connect the plug (a) of the light cord into the ballast (b). If in doubt which way the plug should be installed, install it so that the screw (d) is facing up.
  • Page 15: Inspecting And Cleaning

    Inspecting and Cleaning Inspecting Inspect the following components each time you unpack the LB 1: Make sure that no electrical cords are damaged. If any electrical cords are defective or damaged or if the grounding plug is broken or shorted-out, have a specialist repair it.
  • Page 16: Changing The Bulb

    Operation LB 1 Changing the Bulb Prerequisites Leather gloves and eye protection New bulb Removal Follow the procedure below to remove the bulb. WARNING Cutting hazard. Broken glass from the bulb can cause severe cuts. Always wear leather gloves and eye protection when changing the bulb.
  • Page 17 LB 1 Operation Continued from the previous page. 6. Disconnect the snaps and remove the burst cage (c). 7. With a gloved hand, unscrew the bulb (d) and remove it. Installation Follow the procedure below to install a new bulb.
  • Page 18: Troubleshooting

    Operation LB 1 Troubleshooting Problem Reason Remedy Balloon does not open. The stop bolt is not pulled Pull out the stop bolt and out before attempting to attempt to push down push the black hand grip again. downward. If the balloon still does not...
  • Page 19: Electrical Schematic

    LB 1 Operation Electrical Schematic Ref. Description Ref. Description Power source Lamp Power source plug and cord Transformer Ballast box Capacitor Ballast plug 16A fuse wc_tx000741gb.fm...
  • Page 20: Technical Data

    Technical Data LB 1 Technical Data Machine Item Number 0620340 0620341 Dimensions (l x w x h) mm (in.) 1960 x 1960 x 2622 (77.2 x 77.2 x 103.2) Working height: minimum m (ft.) 2.6 (8.6) maximum m (ft.) 6.2 (20.3) Weight kg (lbs.)
  • Page 21 EC DECLARATION OF CONFORMITY Wacker Construction Equipment AG, Preußenstraße 41, 80809 München hereby certifies that the construction equipment specified hereunder Category Light Balloon Type LB 1 0620340 Item number of equip- 0620341 ment has been produced in accordance with the following standards:...
  • Page 22 Fax: +49 - (0)89-3 54 02-3 90 Wacker Neuson Corporation · P.O. Box 9007 · Menomonee Falls, WI 53052-9007 · Tel. : (262) 255-0500 · Fax: (262) 255-0550 · Tel. : (800) 770-0957 Wacker Asia Pacific Operations · Skyline Tower, Suite 2303, 23/F · 39 Wang Kwong Road, Kowloon Bay, Hong Kong · Tel. +852 2406 60 32 · Fax: +852 2406 60 21...

This manual is also suitable for:

06203410620340

Table of Contents