Download Print this page

Ice Machine Specifications - Scotsman FME 1204 Specification Sheet

Modular air, water, remote cooled flake ice machine
Hide thumbs Also See for FME 1204:

Advertisement

Ice Machine Specifications

EXHAUST
AIR
BACK VIEW
EXHAUST AIR
AIR
WATER INLET
3/8" FLARE
DRAIN
3/4" FPT
BACK VIEW WATER & REMOTE
BACK VIEW AIR
REMOTE LIQUID INLET
3.10 IN
MALE COUPLING
7.9 CM
3/8 IN-1.0 CM
(REMOTE ONLY)
CONDENSER INLET
3/8 IN-1.0 CM F.P.T.
(WATER COOLED ONLY)
BACK VIEW
20.84 IN
WATER &
52.9 CM
REMOTE
CONDENSER DRAIN
1/2 IN-1.3 CM F.P.T.
(WATER COOLED ONLY)
DRAIN
3/4 IN-1.9 CM
F.P.T.
BACK VIEW WATER & REMOTE
All models: Dimensions: W x D x H Unit: 21˝ x 24˝ x 27˝ Shipping Carton: 24
Model
Condenser
Number
Unit
FME1204AS-32B
Air
FME1204WS-32B
Water
FME1204RS-32B
Remote
FME1204AS-3B
Air
FME1204WS-3B
Water
FME1204RS-3B
Remote
All units with Stainless Steel finish.
Refrigerant: R-404A.
REMOTE CONDENSER–Comes with adjustable legs
Dimensions: W x D x H: 24.00˝ x 44.25˝ x 29.25˝ for ERC151
24.00˝ x 44.25˝ x 29.25˝ for ERC302
Model
Number
For Use With
Cond. Unit
Air
Galvanized
ERC151-32A
(1) FME1204
Air
Galvanized
ERC302-32A* (2) FME1204
PRE-CHARGED REFRIGERANT TUBE KITS: 25-Foot, RTE25 • 40-Foot, RTE40 • 75-Foot, RTE75, Refrigerant: R-404A.
*KCMR-230—Fan Relay Kit: Required to connect two FME1204's to one 302-32A
Scotsman's ice machines are not designed for outdoor installations. Scotsman remote condensers are
designed for outdoor installations.
Machine requires voltage indicated on rating name plate. Failures caused by improper voltage are not considered
factory defects. Extended periods of operation at temperatures exceeding limitations constitutes misuse under the
terms of Scotsman Manufacturer's Limited Warranty, resulting in a loss of warranty coverage. Specifications and
design are subject to change without notice.
Y O U ' L L
V A L U E
775 Corporate Woods Parkway • Vernon Hills, IL 60061 • 1-800-SCOTSMAN • Fax: (847) 913-9844
Visit our website at: www.scotsman-ice.com • E-mail: customer.service@scotsman-ice.com
ICE CHUTE
OPENING
ELECTRICAL INLET
9.50 IN
24.1 CM
5.25 IN
3.00 IN
13.3 CM
7.6 CM
2.10 IN
5.3 CM
2.26 IN
5.7 CM
5.87 IN
14.9 CM
3.80 IN
9.7 CM
REMOTE DISCHARGE OUTLET
MALE COUPLING
1/2in-1.3cm
(REMOTE ONLY)
REMOTE CONDENSER
JUNCTION BOX
(REMOTE ONLY)
ELECTRICAL INLET
4.50 IN
11.4 CM
WATER INLET
3/8 IN-1.0 CM FLARE
12.43 IN
31.6 CM
7.30 IN
18.5 CM
5.25 IN
3.00 IN
13.3 CM
7.6 CM
2.66 IN
6.8 CM
4.66 IN
11.8 CM
10.27 IN
26.1 CM
Basic
Max. Fuse
Electrical
Size or HACR
Comp.
Volts/Hz/Phase Circuit Breaker
208-230/60/1
15
208-230/60/1
15
208-230/60/1
20
208-230/60/3
15
208-230/60/3
15
208-230/60/3
15
Electrical
Min. Circuit
Finish
Volts/Hz/
Ampacity
Basic
Phase
No. of Wires
208-230/60/1
2
2.6
208-230/60/1
2
2.6
T H E
D I F F E R E N C E .
6.00 IN/15.2CM MIN.
UTILITY CONNECTIONS
6.20 IN
2.75 IN
15.7 CM
7.0 CM
2.75 IN
7.0 CM
5.75 IN
14.6 CM
PLAN VIEW
PLAN VIEW
24.00 IN
61.0 CM
INTAKE
AIR
SIDE VIEW
LOUVERED ACCESS PANEL
SIDE VIEW
1
/
˝ x 27
1
/
˝ x 32˝
4
2
Min.
Shipping
Circuit
Circuit
Weight
HP
Wires
Ampacity
lbs./kg.
1
2
1
/
2
11.3
215/98
1
2
1
/
2
10.8
210/95
1
2
1
/
2
14.1
230/104
1
2
1
/
3
8.4
210/95
1
2
1
/
3
7.9
230/104
1
1
/
2
3
11.2
230/104
Max Fuse
Size or
HACR Circuit
Braker
15
15
21.00 IN
53.3 CM
27.00 IN
68.6 CM
FRONT VIEW
FRONT VIEW
Power
Water Usage
Consumption
Gallons/100 lbs.
KWH/100 lbs.
Potable
90°F/70° F
90°F/70° F
3.26
12
2.45
12
3.40
12
3.0
12
2.19
12
3.2
12
IMPORTANT OPERATING REQUIREMENTS:
Minimum
Maximum
Air Temperatures
0
0
50
F (10
C)
100
Water Temperatures 40
0
0
F (4.4
C)
100
Remote Cond. Temps -20
0
0
F (-28.9
C)
120
Water Pressures
20 PSIG
120 PSIG
Electrical Voltage
-5%
+10%
Consult Your Local SCOTSMAN Representative At:
TM
NME 654/954
FME 804/1204
Condenser
90°F/70° F
66
66
0
0
F (37.7
C)
0
0
F (37.7
C)
0
0
F (48.9
C)
SF-1204-1 4M 6-06

Advertisement

loading

This manual is also suitable for:

Fme1204as-32bFme1204ws-32bFme1204rs-32bFme1204as-3bFme1204ws-3bFme1204rs-3b