Light Meter
Apollo 1.0 and Apollo 2.0
OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Labino Apollo 1.0

  • Page 1 Light Meter Apollo 1.0 and Apollo 2.0 OPERATING INSTRUCTIONS...
  • Page 2: Table Of Contents

    CONTENTS 1. INTRODUCTION 2. OPERATION 2.1 Turning on Apollo 2.2 The main menu 2.3 Switching off Apollo 2.4 Average reading function 2.5 Change of measuring units 2.6 The peak function 2.7 The hold function 3. PAIRING SENSOR UNITS 4. TECHNICAL INFORMATION 4.1 Batteries 4.2 Operating conditions 4.3 Relative spectral response...
  • Page 3: Introduction

    Each sensor unit has both the UV and white light sensors incorporated. Apollo 1.0 and 2.0 come as a single kit or as a double kit. The single kit includes one reader unit and one wireless sensor unit. A double kit includes one reader unit and two wireless sensor units.
  • Page 4: Operation

    2. OPERATION 2.1 Turning on Apollo a) Turn on the Hand Unit by pressing the “Power On” button (see Figure 1). Figure 1. Hand Unit Power On Screen Hold Peak Arrow Up Enter Arrow Down...
  • Page 5 b) Turn on the Sensor Unit by pressing the “Power On” button. The LED will flash once to confirm (see Figure 2). Note that the Sensor Unit will turn off automatically after 30 s if no connection to the Hand Unit was established or if the Hand Unit was switched off.
  • Page 6: The Main Menu

    2.2 The main menu The main menu is reached when pressing “Enter” (Figure 1). Here, you have the following options: POWER OFF SETTINGS SENSOR UNITS <<< Use the “Arrow Up” and “Arrow Down” function to navigate through the options. Press “Enter” to choose a submenu. Press <<< to return to the measuring screen.
  • Page 7: Average Reading Function

    2.4 Average reading function The average reading function allows integrating over the last 10 or 25 values that are measured by the sensor. a) Select SETTINGS in the main menu. The following submenu opens UV-A: μW/cm VIS: lx AVERAGE: OFF <<<...
  • Page 8: The Peak Function

    d) Return to the measuring screen by either pressing <<< twice or by pressing the “Peak” button once. e) If no key has been pressed within 1 min, the Hand Unit will automatically return to the main menu. 2.6 The peak function After the “Peak”...
  • Page 9: Pairing Sensor Units

    3. PAIRING SENSOR UNITS The Sensor and the Hand Unit are paired by the factory. Only one Hand Unit and one Sensor Unit can be paired at one time. In case of a double kit, the Sensor Unit and the Hand Unit can be paired manually. a) Select SENSOR UNITS in the main menu.
  • Page 10: Technical Information

    405 nm shall be less than 2%. 5. CALIBRATION The recommended calibration interval is six months and is done by Labino or a Labino authorized calibration center. These centers can be found online at www.labino.com.
  • Page 11 Figure 7. Relative spectral responsivities of the Apollo 1.0 and the Apollo 2.0 UV-radiometers...
  • Page 12 Distributed by: DISTRIBUTOR: Labino AB shall not be held liable for any errors or omissions resulting from the test procedures that were used in validating performance of any Labino AB product nor for unforeseen errors or omissions in digital or printed material.