Mitsubishi Electric MUZ-GL09NA-U1 Service Manual page 22

Split-type air conditioners unit outdoor unit
Hide thumbs Also See for MUZ-GL09NA-U1:
Table of Contents

Advertisement

MUZ-GL24NA MUY-GL24NA
Refrigerant pipe ø 5/8 ( ø15.88)
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 3/8 ( ø9.52)
(with heat insulator)
MUZ-GL24NAH
Refrigerant pipe ø 5/8 ( ø15.88)
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 3/8 ( ø9.52)
(with heat insulator)
OBH733D
Muffler
with #100 mesh strainer
4-way valve
Stop valve
(with service port)
Discharge
temperature
thermistor
Service
RT62
port
Strainer
#100
Stop valve
Capillary tube
O.D.0.157 × I.D.0.094
× 3-15/16
(ø 4.0 ×ø 2.4 × 100)
4-way valve
Stop valve
(with service port)
Service
port
CHECK
VALVE
Strainer
#100
Stop valve
Capillary tube
O.D.0.118 × I.D.0.071
× 21-21/32
(ø 3.0 ×ø 1.8 × 550)
Service port
Defrost
thermistor
RT61
(MUZ)
Compressor
Outdoor heat
exchanger
temperature
thermistor
RT68
LEV
Strainer
#100
Refrigerant flow in cooling
Refrigerant flow in heating (MUZ)
Muffler
#100
Service
port
Discharge
temperature
thermistor
Defrost
RT62
thermistor
RT61
Compressor
LEV
Strainer
#100
Capillary tube
O.D.0.157 × I.D.0.094
× 3-15/16
(ø 4.0 ×ø 2.4 × 100)
22
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
R.V. coil (MUZ)
heating ON
cooling OFF
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor
RT68
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating

Hide quick links:

Advertisement

Table of Contents
loading