Analog Module User Manual

1.

Product Model List and Dimension

Ethernet Model
24VDC
S08AI-e
0.11A
S08AO-e
0.25A
S08XA-e
0.18A
84.0
1
8
9
10
2
AI0I
AI0V
AI0G
GND
A+
AI1I
AI1V
AI1G
AI2I
AI2V
AI2G
AI3I
AI3V
0 1 2 3
3
AI
4
POW
S08AI
LINK
ON
DIP
AI
1 2 3 4
4 5 6 7
AI6I
AI6V
AI6G
AI7I
AI7V
5
AI4I
AI4V
AI4G
AI5I
AI5V
6
7
1.
Fixed hole
2.
Removable terminal screw
3.
Terminal definition
4.
Module expansion port
5.
DIP switch(4-channel module without DIP switch)
6.
External power supply terminal
(DC24V and AC220V, Generally powered by the host PLC)
7.
Guide rail buckle
2.

Indicator Description

PWR: power indicator. green, constant light -Power normal; Not light - Power abnormal.
1
LINK: multi-status indicator . three colors (Red. Yellow. Green), as follow:
2
Reference processing mode
Normal
Parallel power supply not
enough, must connect to external
power supply
Firmware upgrade failed,
reupgrade the module firmware
Hardware failure and
maintenance
Ethernet Model
220VAC
S08AI2-e
7.9W
S08AO2-e
12.4W
S08XA2-e
10.4W
61.5
70.0
11
12
13
14
B-
RS485
AI3G
AI7G
AI5G
Module bus state
No communication of module
MPU has identified the module but no
communication
Serial or parallel port in communication
Without serial or parallel port in
communication
With serial or parallel port in communication
Without serial or parallel port in
communication
With serial or parallel port in communication
Without serial or parallel port in
communication
With serial or parallel port in communication
Model
24VDC
S04AI
0.07A
S04AO
0.15A
S04XA
0.1A
S08AI
0.08A
S08AO
0.22A
S08XA
0.15A
0 1 2 3
AI
POW
S08XA2
LINK
AQ
0 1 2 3
84.5
93.0
15
8.
Removable terminal
9.
Analog input channel indicator
10.
RS485 communication port
11.
PWR power indicator, LINK module communication indicator
12.
Module expansion port
13.
Transparent cover of module terminal
14.
Module nameplate
15.
35mm DIN guide rail
No light
Constant light in green
Green jitter: indicator on 30ms and off 30ms
Yellow flicker: indicator on 0.5s and off 0.5s
Yellow is darkened and jitter alternately: indicator off 0.5s and
jitter 0.5s
Red flicker: indicator on 0.5s and off 0.5s
Red is darkened and jitter alternately: indicator off 0.5s and
jitter 0.5s
Constant light in red
Red jitter quickly: indicator on 30ms and off 30ms
3 / 18
Haiwell PLC - Analog Module User Manual
Model
220VAC
S04AI2
7W
S04AO2
8.8W
70×95×82mm
S04XA2
7.8W
S08AI2
7.3W
S08AO2
11.8W
93×95×82mm
S08XA2
9.8W
LINK indicator state
Dimension

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents